Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9632
25A0
Slave Device 6: Flow Run Config: Gas Fraction
FP
—
RW
9633
25A1
Slave Device 6: Flow Run Config: Plate Diameter
FP
inch
RW
9634
25A2
Slave Device 6: Flow Run Config: Pipe Diameter
FP
inch
RW
9635
25A3
Slave Device 6: Flow Run Config: Cone Beta
FP
—
RW
9636
25A4
Slave Device 6: Flow Run Config: Nominal Value
FP
—
RW
9637
25A5
Slave Device 6: TFM Config: T1 Nominal Factor
FP
pulses/gal
RW
9638
25A6
Slave Device 6: TFM Config: T2 Nominal Factor
FP
pulses/gal
RW
Slave 7 Configuration (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9651
25B3
Slave Device 7: Flow Run Config: Atmospheric
Pressure
FP
psia
RW
9652
25B4
Slave Device 7: Flow Run Config: Carbon Dioxide
FP
—
RW
9653
25B5
Slave Device 7: Flow Run Config: Nitrogen
FP
—
RW
9654
25B6
Slave Device 7: Flow Run Config: Specific Gravity
FP
—
RW
9655
25B7
Slave Device 7: Flow Run Config: Heating Value
FP
MMBtu/ft³
RW
9656
25B8
Slave Device 7: Flow Run Config: Oil Density
FP
lbm/ft³
RW
9657
25B9
Slave Device 7: Flow Run Config: Gas Fraction
FP
—
RW
9658
25BA
Slave Device 7: Flow Run Config: Plate Diameter
FP
inch
RW
9659
25BB
Slave Device 7: Flow Run Config: Pipe Diameter
FP
inch
RW
9660
25BC
Slave Device 7: Flow Run Config: Cone Beta
FP
—
RW
9661
25BD
Slave Device 7: Flow Run Config: Nominal Value
FP
—
RW
9662
25BE
Slave Device 7: TFM Config: T1 Nominal Factor
FP
pulses/gal
RW
9663
25BF
Slave Device 7: TFM Config: T2 Nominal Factor
FP
pulses/gal
RW
Slave 8 Configuration (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
9676
25CC
Slave Device 8: Flow Run Config: Atmospheric
Pressure
FP
psia
RW
9677
25CD
Slave Device 8: Flow Run Config: Carbon Dioxide
FP
—
RW
9678
25CE
Slave Device 8: Flow Run Config: Nitrogen
FP
—
RW
9679
25CF
Slave Device 8: Flow Run Config: Specific Gravity
FP
—
RW
9680
25D0
Slave Device 8: Flow Run Config: Heating Value
FP
MMBtu/ft³
RW
9681
25D1
Slave Device 8: Flow Run Config: Oil Density
FP
lbm/ft³
RW
9682
25D2
Slave Device 8: Flow Run Config: Gas Fraction
FP
—
RW
9683
25D3
Slave Device 8: Flow Run Config: Plate Diameter
FP
inch
RW
9684
25D4
Slave Device 8: Flow Run Config: Pipe Diameter
FP
inch
RW
9685
25D5
Slave Device 8: Flow Run Config: Cone Beta
FP
—
RW
82
Section 1
Scanner 3100 Modbus Protocol
Содержание Scanner 3100
Страница 1: ...Scanner 3100 Modbus Protocol Manual Manual No 50280809 Rev 04 ...
Страница 192: ...This page is left blank intentionally 192 Section 2 Scanner 3100 Modbus Protocol ...
Страница 196: ...This page is left blank intentionally A 4 Appendix A Scanner 3100 Modbus Protocol ...
Страница 198: ......