Input
Fail Condition
MVT
Serial number is not read at boot-up
Temperature Sensor (TSEN): < -100°C or > 200°C
Static Pressure: < -10 psi or > 10000 psi
Differential Pressure: < -2000 in H20 or > 2000 in
H20
Flow Run Status Definitions
Bit Position
Flow Run Status When Bit=1
0
Disabled
1
High
2
High High
3
Low
4
Low Low
5
Fail
6
Overridden
7
Maintenance
8
Data Input Change
9
Static Pressure Input Invalid
10
Static Pressure is Input Fail
11
Static Pressure is Category Mismatch
12
Process Temperature Input Invalid
13
Process Temperature is Input Fail
14
Process Temperature is Category Mismatch
15
Differential Pressure Input Invalid
16
Differential Pressure Input Fail
17
Differential Pressure is Category Mismatch
18
Square Root of Differential Pressure Input Invalid
19
Square Root of Differential Pressure is Input Fail
20
Square Root of Differential Pressure Category Mismatch
21
Uncorrected Accumulation Input Invalid
22
Uncorrected Accumulation Input Fail
23
Uncorrected Accumulation is Category Mismatch
24
Gas Fraction Input Input Fail
25
Oil Fraction Input Input Fail
26 – 27
—
28
Flow Calculation
29
Fluid Calculation
30
Flowing
31
Calculation Change
130
Section 2
Scanner 3100 Modbus Protocol
Содержание Scanner 3100
Страница 1: ...Scanner 3100 Modbus Protocol Manual Manual No 50280809 Rev 04 ...
Страница 192: ...This page is left blank intentionally 192 Section 2 Scanner 3100 Modbus Protocol ...
Страница 196: ...This page is left blank intentionally A 4 Appendix A Scanner 3100 Modbus Protocol ...
Страница 198: ......