Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
5859
16E3
Flow Run 2: HFluid: Correction For Pressure On
Liquid
FP
—
RO
5861
16E5
Flow Run 2: HFluid: Composite Correction On Liquid
FP
—
RO
5863
16E7
Flow Run 2: HFluid: Gas To Liquid Volume Ratio
FP
—
RO
5865
16E9
Flow Run 2: HFluid: Liquid Oil Mass Fraction
FP
—
RO
5867
16EB
Flow Run 2: HFluid: Liquid Shrinkage Factor
FP
—
RO
5869
16ED
Flow Run 2: HFluid: Liquid BSW
FP
—
RO
5871
16EF
Flow Run 2: HFluid: Liquid Oil Base Density
FP
lbm/ft³
RO
5873
16F1
Flow Run 2: HFluid: Liquid Oil Flowing Density
FP
lbm/ft³
RO
5875
16F3
Flow Run 2: HFluid: Liquid Water Base Density
FP
lbm/ft³
RO
5877
16F5
Flow Run 2: HFluid: Liquid Water Flowing Density
FP
lbm/ft³
RO
5879
16F7
Flow Run 2: HFluid: Liquid Composite Flowing
Density
FP
lbm/ft³
RO
5881
16F9
Flow Run 2: HFlow: Reference Orifice Diameter
FP
inch
RO
5883
16FB
Flow Run 2: HFlow: Reference Meter Tube Inside
Diameter
FP
inch
RO
5885
16FD
Flow Run 2: HFlow: Reference Orifice Temperature
FP
°F
RO
5887
16FF
Flow Run 2: HFlow: Reference Meter Tube
Temperature
FP
°F
RO
5889
1701
Flow Run 2: HFlow: Orifice Alpha
FP
1/°F
RO
5891
1703
Flow Run 2: HFlow: Meter Tube Alpha
FP
1/°F
RO
5893
1705
Flow Run 2: HFlow: Flowing Orifice Diameter
FP
inch
RO
5895
1707
Flow Run 2: HFlow: Flowing Meter Tube Inside
Diameter
FP
inch
RO
5897
1709
Flow Run 2: HFlow: Flowing Weep Hole Diameter
FP
inch
RO
5899
170B
Flow Run 2: HFlow: Weep Hole Adjustment Factor
FP
—
RO
5901
170D
Flow Run 2: HFlow: Flowing Beta Ratio
FP
—
RO
5903
170F
Flow Run 2: HFlow: Flowing Discharge Coefficient
FP
—
RO
5905
1711
Flow Run 2: HFlow: Flowing Meter Factor
FP
—
RO
5907
1713
Flow Run 2: HFlow: Annubar C1 Coefficient
FP
—
RO
5909
1715
Flow Run 2: HFlow: Annubar C2 Coefficient
FP
—
RO
5911
1717
Flow Run 2: HFlow: Wedge Calibration Factor
FP
—
RO
5913
1719
Flow Run 2: HFlow: Flowing Differential Pressure
FP
"H2O@68F
RO
5915
171B
Flow Run 2: HFlow: Flowing Temperature
FP
°F
RO
5917
171D
Flow Run 2: HFlow: Flowing Upstream Pressure
FP
psia
RO
5919
171F
Flow Run 2: HFlow: Flowing Square Root Of Diff
Pres
FP
—
RO
5921
1721
Flow Run 2: HFlow: Uncorrected Accumulation
FP
—
RO
5923
1723
Flow Run 2: HFlow: Stability Index
FP
—
RO
5925
1725
Flow Run 2: HFlow: Reynolds Number Pipe
FP
—
RO
5927
1727
Flow Run 2: HFlow: Expansion Factor
FP
—
RO
159
Scanner 3100 Modbus Protocol
Section 2
Содержание Scanner 3100
Страница 1: ...Scanner 3100 Modbus Protocol Manual Manual No 50280809 Rev 04 ...
Страница 192: ...This page is left blank intentionally 192 Section 2 Scanner 3100 Modbus Protocol ...
Страница 196: ...This page is left blank intentionally A 4 Appendix A Scanner 3100 Modbus Protocol ...
Страница 198: ......