Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
7229
1C3D
Pulse Input 1: Holding: Previous Daily Total
FP
bbl
RO
7230
1C3E
Pulse Input 1: Holding: Previous Interval Total
FP
bbl
RO
7231
1C3F
Pulse Input 2: Holding: Grand Total
FP
bbl
RO
7232
1C40
Pulse Input 2: Holding: Flow Rate
FP
bbl/day
RO
7233
1C41
Pulse Input 2: Holding: Daily Total
FP
bbl
RO
7234
1C42
Pulse Input 2: Holding: Interval Total
FP
bbl
RO
7235
1C43
Pulse Input 2: Holding: Previous Daily Total
FP
bbl
RO
7236
1C44
Pulse Input 2: Holding: Previous Interval Total
FP
bbl
RO
7237
1C45
Pulse Input 3: Holding: Grand Total
FP
bbl
RO
7238
1C46
Pulse Input 3: Holding: Flow Rate
FP
bbl/day
RO
7239
1C47
Pulse Input 3: Holding: Daily Total
FP
bbl
RO
7240
1C48
Pulse Input 3: Holding: Interval Total
FP
bbl
RO
7241
1C49
Pulse Input 3: Holding: Previous Daily Total
FP
bbl
RO
7242
1C4A
Pulse Input 3: Holding: Previous Interval Total
FP
bbl
RO
7243
1C4B
Pulse Input 1: Holding: Frequency
FP
Hz
RO
7244
1C4C
Pulse Input 1: Holding: Active K Factor
FP
pulses/gal
RO
7245
1C4D
Pulse Input 2: Holding: Frequency
FP
Hz
RO
7246
1C4E
Pulse Input 2: Holding: Active K Factor
FP
pulses/gal
RO
7247
1C4F
Pulse Input 3: Holding: Frequency
FP
Hz
RO
7248
1C50
Pulse Input 3: Holding: Active K Factor
FP
pulses/gal
RO
7249
1C51
Analog Output 1: Holding: Output
FP
mA
RW
7250
1C52
Analog Output 1 PID: Holding: Process Value Value
FP
—
RO
7251
1C53
Analog Output 1 PID: Holding: Static Pressure
Value
FP
—
RO
7252
1C54
Analog Output 1 PID: Holding: Test Value
FP
—
RO
7253
1C55
Analog Output 1 PID: Holding: Output
FP
—
RO
7254
1C56
Analog Output 2: Holding: Output
FP
mA
RW
7255
1C57
Analog Output 2 PID: Holding: Process Value Value
FP
—
RO
7256
1C58
Analog Output 2 PID: Holding: Static Pressure
Value
FP
—
RO
7257
1C59
Analog Output 2 PID: Holding: Test Value
FP
—
RO
7258
1C5A
Analog Output 2 PID: Holding: Output
FP
—
RO
7259
1C5B
Analog Output 1 PID: Configuration: Setpoint
Tolerance
FP
—
RW
7260
1C5C
Analog Output 1 PID: Configuration: Setpoint Dead
Band
FP
—
RW
7261
1C5D
Analog Output 1 Pressure Override: Configuration:
Setpoint Tolerance
FP
—
RW
7262
1C5E
Analog Output 1 Pressure Over: Configuration:
Setpoint Dead Band
FP
—
RW
44
Section 1
Scanner 3100 Modbus Protocol