Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
6377
18E9
Pulse Input 3: Holding: Daily Total
FP
bbl
RO
6379
18EB
Pulse Input 3: Holding: Interval Total
FP
bbl
RO
6381
18ED
Pulse Input 3: Holding: Previous Daily Total
FP
bbl
RO
6383
18EF
Pulse Input 3: Holding: Previous Interval Total
FP
bbl
RO
6385
18F1
Pulse Input 1: Holding: Frequency
FP
Hz
RO
6387
18F3
Pulse Input 1: Holding: Active K Factor
FP
pulses/gal
RO
6389
18F5
Pulse Input 2: Holding: Frequency
FP
Hz
RO
6391
18F7
Pulse Input 2: Holding: Active K Factor
FP
pulses/gal
RO
6393
18F9
Pulse Input 3: Holding: Frequency
FP
Hz
RO
6395
18FB
Pulse Input 3: Holding: Active K Factor
FP
pulses/gal
RO
6397
18FD
Analog Output 1: Holding: Output
FP
mA
RO
6399
18FF
Analog Output 1 PID: Holding: Process Value Value
FP
—
RO
6401
1901
Analog Output 1 PID: Holding: Static Pressure Value
FP
—
RO
6403
1903
Analog Output 1 PID: Holding: Test Value
FP
—
RO
6405
1905
Analog Output 1 PID: Holding: Output
FP
—
RO
6407
1907
Analog Output 2: Holding: Output
FP
mA
RO
6409
1909
Analog Output 2 PID: Holding: Process Value Value
FP
—
RO
6411
190B
Analog Output 2 PID: Holding: Static Pressure Value
FP
—
RO
6413
190D
Analog Output 2 PID: Holding: Test Value
FP
—
RO
6415
190F
Analog Output 2 PID: Holding: Output
FP
—
RO
Slave 1 Configuration (Floating Points)
Register
(Decimal)
Register
(Hex)
Description
Data
Type
Units
Access
7001
1B59
Slave Device 1: Flow Run Config: Atmospheric
Pressure
FP
psia
RW
7003
1B5B
Slave Device 1: Flow Run Config: Carbon Dioxide
FP
—
RW
7005
1B5D
Slave Device 1: Flow Run Config: Nitrogen
FP
—
RW
7007
1B5F
Slave Device 1: Flow Run Config: Specific Gravity
FP
—
RW
7009
1B61
Slave Device 1: Flow Run Config: Heating Value
FP
MMBtu/ft³
RW
7011
1B63
Slave Device 1: Flow Run Config: Oil Density
FP
lbm/ft³
RW
7013
1B65
Slave Device 1: Flow Run Config: Gas Fraction
FP
—
RW
7015
1B67
Slave Device 1: Flow Run Config: Plate Diameter
FP
inch
RW
7017
1B69
Slave Device 1: Flow Run Config: Pipe Diameter
FP
inch
RW
7019
1B6B
Slave Device 1: Flow Run Config: Cone Beta
FP
—
RW
7021
1B6D
Slave Device 1: Flow Run Config: Nominal Value
FP
—
RW
7023
1B6F
Slave Device 1: TFM Config: T1 Nominal Factor
FP
pulses/gal
RW
7025
1B71
Slave Device 1: TFM Config: T2 Nominal Factor
FP
pulses/gal
RW
165
Scanner 3100 Modbus Protocol
Section 2
Содержание Scanner 3100
Страница 1: ...Scanner 3100 Modbus Protocol Manual Manual No 50280809 Rev 04 ...
Страница 192: ...This page is left blank intentionally 192 Section 2 Scanner 3100 Modbus Protocol ...
Страница 196: ...This page is left blank intentionally A 4 Appendix A Scanner 3100 Modbus Protocol ...
Страница 198: ......