Bit Position
Flow Run Status When Bit=1
2
High High
3
Low
4
Low Low
5
Fail
6
Overridden
7
Maintenance
8
Data Input Change
9
Static Pressure Input Invalid
10
Static Pressure is Input Fail
11
Static Pressure is Category Mismatch
12
Process Temperature Input Invalid
13
Process Temperature is Input Fail
14
Process Temperature is Category Mismatch
15
Differential Pressure Input Invalid
16
Differential Pressure Input Fail
17
Differential Pressure is Category Mismatch
18
Square Root of Differential Pressure Input Invalid
19
Square Root of Differential Pressure is Input Fail
20
Square Root of Differential Pressure Category Mismatch
21
Uncorrected Accumulation Input Invalid
22
Uncorrected Accumulation Input Fail
23
Uncorrected Accumulation is Category Mismatch
24
Gas Fraction Input Input Fail
25
Oil Fraction Input Input Fail
26 – 27
—
28
Flow Calculation
29
Fluid Calculation
30
Flowing
31
Calculation Change
Fluid Status Definitions
Bit Position
Fluid Status When Bit=1
0
Fluid Change
1
No Temperature Change
2
No Pressure Change
3
Ideal Properties Incorrect
4
Molar Mass Incorrect
5
Ideal Absolute Viscosity Incorrect
6
Base Density Incorrect
7
Gas to Liquid Volume Ratio Incorrect
8
Liquid Oil Mass Fraction Incorrect
9
Normal Viscosity Incorrect
23
Scanner 3100 Modbus Protocol