Event
Event Name
Enron
Change
Flags
System Com-
mand Code
As Found
As Left
Flow Info Reset
Alarm
Square Root Differential
Pressure Incorrect Reset
0x0280 (640)
0x81A0 (33184)
Unused
Object Index
Stability Warning Reset
0x0280 (640)
0x81A1 (33185)
Unused
Object Index
Meter Material Invalid
Reset
0x0280 (640)
0x81A2 (33186)
Unused
Object Index
Meter Alpha Override
Invalid Reset
0x0280 (640)
0x81A3 (33187)
Unused
Object Index
Meter Corrected Diameter
Invalid Reset
0x0280 (640)
0x81A4 (33188)
Unused
Object Index
Orifice Material Invalid
Reset
0x0280 (640)
0x81A5 (33189)
Unused
Object Index
Orifice Alpha Override
Invalid Reset
0x0280 (640)
0x81A6 (33190)
Unused
Object Index
Orifice Corrected Diameter
Invalid Reset
0x0280 (640)
0x81A7 (33191)
Unused
Object Index
Reference Beta Ratio
Invalid Reset
0x0280 (640)
0x81A8 (33192)
Unused
Object Index
Flowing Beta Ratio Invalid
Reset
0x0280 (640)
0x81A9 (33193)
Unused
Object Index
Gas Expansion Factor
Invalid Reset
0x0280 (640)
0x81AA (33194)
Unused
Object Index
Meter Type Invalid Reset
0x0280 (640)
0x81AB (33195)
Unused
Object Index
Meter Reference Diameter
Invalid Reset
0x0280 (640)
0x81AC (33196)
Unused
Object Index
Orifice Reference Diameter
Invalid Reset
0x0280 (640)
0x81AD (33197)
Unused
Object Index
Orifice Greater Than Meter
Diameter Reset
0x0280 (640)
0x81AE (33198)
Unused
Object Index
Fluid Type Incorrect for
Flow Calculation Set
0x8280 (33408)
0x81AF (33199)
Unused
Object Index
Reynolds Number Low for
Flow Calculation Set
0x8280 (33408)
0x81B0 (33200)
Unused
Object Index
Reynolds Number High for
Flow Calculation Set
0x8280 (33408)
0x81B1 (33201)
Unused
Object Index
Beta Ratio Low for Flow
Calculation Set
0x8280 (33408)
0x81B2 (33202)
Unused
Object Index
Beta Ratio High for Flow
Calculation Set
0x8280 (33408)
0x81B3 (33203)
Unused
Object Index
Multiphase Root Search
Failure Set
0x8280 (33408)
0x81B4 (33204)
Unused
Object Index
Multiphase Non-fatal
Convergence Fail Set
0x8280 (33408)
0x81B5 (33205)
Unused
Object Index
Lockhart-Martinelli Warning
(Xlm > 0.3) Set
0x8280 (33408)
0x81B6 (33206)
Unused
Object Index
Lockhart-Martinelli Warning
(Xlm > 0.4) Set
0x8280 (33408)
0x81B7 (33207)
Unused
Object Index
98
Section 2
Scanner 3100 Modbus Protocol
Содержание Scanner 3100
Страница 1: ...Scanner 3100 Modbus Protocol Manual Manual No 50280809 Rev 04 ...
Страница 192: ...This page is left blank intentionally 192 Section 2 Scanner 3100 Modbus Protocol ...
Страница 196: ...This page is left blank intentionally A 4 Appendix A Scanner 3100 Modbus Protocol ...
Страница 198: ......