10 11 TS 1 2 3 3P 4 5 7
ON
OFF
2
1
3
4
5
6
7
8
9
10
ON
FUSE
ACCESS.
315mA
LINE FUSE 5A
+ AUT.CL. - + PAR.OP. -
+ OPER.TIME -
AF
CONTROL BOARD
ZC3
CH1
CH2
CLOSE
OPEN
1 2 3 4 5 6 7 8 9 10 1
1 12
V1 V2 V3 V4 V5
04 05 06 07 08
CONTROL BOARD
1A
FUSE
FUSE
ACCESS.
315mA
LINE FUSE 5A
+ AUT.CL. - + PAR.OP. -
+ OPER.TIME -
AF
CONTROL BOARD
ZC3
CH1
CH2
CLOSE
OPEN
1 2 3 4 5 6 7 8 9 10 1
1 1
2
V1 V2 V3 V4 V
5
04 05 06 07 0
8
CONTROL BOARD
1A
FUSE
24 12 0
L1
L2
V
E
W
U
E1
EX
VS
L1T
CT
L2T
ON
11 12 13 14 15 16 17 18 19 20
ON
1 2 3 4 5 6 7 8 9 10
10 11 TS 1 2 3 3P 4 5 7
2 C1 CX FC FA F B1 B2
+
E D
2
1
Pa
g.
8
-
manual
co
de
3
1
9
S
3
3
E
N
31
9
S
3
3
E
N
ve
r.
5
0
6
/2
01
5
© C
A
M
E S
.p.
A
.- T
he d
ata a
nd i
nf
or
m
ati
on i
n th
is m
an
ua
l m
ay b
e c
ha
ng
ed at a
ny ti
m
e a
nd w
ith
ou
t o
bl
ig
ati
on o
n th
e p
art of C
A
M
E S
.p.
A
. to n
otify s
ai
d c
ha
ng
es.
Command devices
Stop button (
N.C. contact
)
Gate stop button with exclusion of automatic closing, to resu-
me movement press command button or transmitter button.
Ket switch selector and/or opening button
(
N.O. contact
)
- Command for gate opening.
Key switch selector and/or command button
(
N.O. contact
)
- Gate opening and closing commands, pressing the button or
turning the key switch selector, the gate inverts its movement
or stops depending on selection made on the DIP switches (see
selecting functions, DIP switches 1-10)
Key switch selector and/or opening button
(
N.O. contact
)
- Opening gate for pedestrian passage. The opening time can
be adjusted via the PART. OPEN. The automatic closing time is
adjustable via DIP-switch 12.
N.B.
: All I is buttons (N.C.) All (N.C.) contacts and buttons
7 Selecting functions
1 ON
-
Automatic closing activated; (1OFF - deactivated)
2 ON
-
“Open-stop-close-stop” with button (2-7) and radio command (AF card plugged in) activated;
2 OFF
-
“Open-close” with button (2-7) and radio command (AF card plugged in) activated;
3 ON
-
"Open only" with radio command (AF card plugged in) activated; (3 OFF - deactivated)
4 OFF
-
"Man on" (excludes the radio command) deactivated; (4ON - activated)
5 ON
-
Pre-flashing activated; (5OFF - deactivated)
6 ON
-
Obstacle detection activated; (6 OFF - deactivated)
7 OFF
-
Reopening while closing activated; with safety device connected to terminals 2-C1, (if unused, set DIP switch
to ON)
8 OFF-9 OFF -
Reclosing while opening activated; with safety device connected to terminals 2-CX;
8 OFF-9 ON
-
Partial stop activated; with safety device connected to terminals 2-CX; (if the devices on 2-CX are unused, set
DIP switch 8 to ON)
10 OFF
-
Total stop activated by button which is situated on terminals 1-2, (if unused, set DIP switch to ON)
Key switch selector and/or opening button
(
N.O. contact
)
- Gate closing command.
DIP-SWITCH (1-10)
if unused
Содержание ZC3
Страница 1: ...RU IT RU Fran ais FR Fran ais FR English EN English EN Italiano IT Italiano IT 319S33...
Страница 15: ...INSTALLATION MANUAL ZC3 CONTROL PANEL FOR 230 V GEARMOTORS English EN 319S33EN...
Страница 29: ...MANUEL D INSTALLATION ZC3 ARMOIRE DE COMMANDE POUR MOTOR DUCTEURS EN 230 V Fran ais FR 319S33FR...
Страница 43: ...ZC3 230 RU 319S33RU...
Страница 46: ...4 319S33RU 319S33RU 5 06 2015 CAME S p A CAME S p A 3 1 6 2 20 3 5 3 5 5 1 5 2...