55
•
Chimney connector is glowing red.
•
Extreme heat coming from the furnace. If this occurs,
DO NOT OPEN THE DOOR
. Shut-off the air inlet opening
completely, and wait until the glow has completely subsided.
16.8.5. WOOD AS HEATING FUEL
WARNING
NEVER BURN WASTE, GAZOLINE, NAPHTA, MOTOR OIL OR ANY OTHER SIMILAR PRODUCT.
We recommend that you burn dry hard wood only.
There are two important factors to be considered when choosing a type of wood: the moisture content and the wood
density. Hardwood, oak and beech for example, will provide better results because of the high density and minimal tar
produced during combustion. It is highly recommended to use wood that has been dried for at least six months.
DO NOT USE COAL AS HEATING FUEL IN THIS APPLIANCE.
Whenever a high rate of smoke is noticed in the room, you must:
1. Open doors and windows.
2. Make sure the furnace door is closed as well as the damper (if necessary, lower the thermostat starting point or
unhook the damper chain and close the barometric draft control manually).
3. When the furnace has cooled down, inspect the chimney to detect obstructions and consult a specialist to
determine the cause of the smoke spillage.
16.8.6. PROLONGED POWER FAILURE
In case of prolonged power failure (over 10 minutes), to reduce the risk of overheating, it is recommended to heat
moderately and to open the furnace filter compartment in order to facilitate air circulation by natural gravity around the
firebox of the Caddy wood furnace.
16.8.7. CHIMNEY FIRES
This might occur when the fire gets extremely hot. Burning cardboard, branches, or small pieces of wood can ignite
the creosote residue accumulated in the evacuation flue system. The usual signs are:
1. Rumbling.
2. The flue gets extremely hot (red).
3. Flames or sparks are coming out of the chimney.
4. In case of a chimney fire, call your local fire department immediately and sprinkle the roof around the chimney with
water.
Make sure that the furnace door is closed as well as the damper (if necessary, lower the thermostat starting point or
release the chain from the damper and close the barometric draft control manually).
If the fire gets uncontrollable due to an improper use or because the draft is too strong, follow the same procedure as
in a chimney fire except that you will have to
OPEN
the barometric draft control manually.
16.8.8. LOCAL FIRE DEPARTMENT
Phone number: ___________________________________
ALWAYS KEEP THE DOOR AND THE ASH DRAWER CLOSED
(except for lighting and maintenance).
Содержание PF01015
Страница 10: ...10 ADD ON WOOD ONLY WOOD ELECTRIC WOOD OIL ...
Страница 13: ...13 INSTALLATION AND OPERATION INSTRUCTIONS CADDY ADD ON SERIAL INSTALLATION PF01015 ...
Страница 16: ...16 Option 3 Option 4 ...
Страница 17: ...17 EXAMPLE 1 EXAMPLE 2 ...
Страница 23: ...23 REQUIRES 2 RELAY SPNO SPNC WHITE ROGERS P N 90 380 NOT INCLUDED AND 24V AVAILABLE ON EXISTING FURNACE ...
Страница 24: ...24 13 ELECTRICAL DIAGRAM FOR SERIAL FURNACE VIA MOTOR REQUIRES 1 RELAY 51035 WITH 1 JUNCTION BOX NOT INCLUDED ...
Страница 63: ...63 20 GENERAL ELECTRICAL DIAGRAM STANDALONE FURNACE ...
Страница 64: ...64 21 ELECTRICAL DIAGRAM FOR PARALLEL FURNACE ...
Страница 65: ...65 22 ELECTRICAL DIAGRAM FOR ELECTRIC UNIT ...
Страница 78: ...78 31 ELECTRICAL DIAGRAM BECKETT OIL UNIT ...
Страница 79: ...79 32 ELECTRICAL DIAGRAM RIELLO OIL UNIT ...
Страница 81: ...81 33 4 AIR CONDITIONNING DAMPER 33 5 HUMIDIFIER 33 6 HEAT PUMP ...
Страница 82: ...82 34 EXPLODED VIEW AND PART LIST ...
Страница 83: ...83 ...
Страница 84: ...84 ...
Страница 85: ...85 ...
Страница 86: ...86 ...
Страница 87: ...87 ...
Страница 88: ...88 ...
Страница 89: ...89 ...