51
16.4. ADDING AUXILIARY HEATING SOURCE AND SELECTION OF OPTIONS
To add an auxiliary source of heating or to add options to your furnace, press the "Settings" button. On the “MAIN”
page, choose “SETUP” and “OPTIONS”.
By default, no auxiliary source of heating or options are selected. To select an option, simply press the white square to
the left of the desired option. When an option is chosen, the selected square turns green.
To confirm the selection of your options, press the button '' SAVE + EXIT ''. This step takes you to a list of questions
about your selections that are essential for their good functioning.
16.4.1. TRANSITION TO AN AUXILIARY HEAT SOURCE
When there is a demand for heat, the furnace checks the temperature in the plenum. If the temperature is beyond the
KIP, the fan will turn on. If the temperature is below the KIP, the furnace will wait the "Rise Time" delay and check the
temperature again in the plenum. If the temperature in the plenum goes up 20°F but has not reached the KIP, the
furnace will wait for additional time ("KIP Time") and recheck the temperature in the plenum. If the temperature has not
reached the KIP, the auxiliary heating will start. The icon "Wood" will turn yellow and the auxiliary heat icon will turn
green.
For the electrical element and/or the oil unit, the fan starts as soon as the thermostat asks for heat. In other words, for
safety reasons, the fan does not wait for the hot air plenum to reach a predetermined minimum temperature.
The furnace remembers what heating source was used in the last request of the thermostat. If the last heating demand
was met by the auxiliary heater, the furnace automatically start this one.
To restart the furnace using the wood mode, go on the touch screen on the main page and press on the wood icon.
The icon will become green and the auxiliary heating source icon will become yellow.
16.4.2. TRANSITION SETTINGS
It is possible to slightly adjust the transition settings from the wood option to the auxiliary source of heating. To do this,
go to the "MAIN" page on the touch screen under the "SETUP" option and choose "WOOD SETUP ". On this page,
you can change the KIP, KOP, the Rise Time and KIP Time.
KIP (Kick-In point): Temperature of the plenum where the fan turns on.
KOP (Kick-Out point): Temperature of the plenum when the fan stops.
Rise Time: Time allowed for plenum temperature to increase by 20 ° F.
KIP Time: Additional time allowed to reach the KIP when the Rise Time ended with an increase of 20°F.
Содержание PF01015
Страница 10: ...10 ADD ON WOOD ONLY WOOD ELECTRIC WOOD OIL ...
Страница 13: ...13 INSTALLATION AND OPERATION INSTRUCTIONS CADDY ADD ON SERIAL INSTALLATION PF01015 ...
Страница 16: ...16 Option 3 Option 4 ...
Страница 17: ...17 EXAMPLE 1 EXAMPLE 2 ...
Страница 23: ...23 REQUIRES 2 RELAY SPNO SPNC WHITE ROGERS P N 90 380 NOT INCLUDED AND 24V AVAILABLE ON EXISTING FURNACE ...
Страница 24: ...24 13 ELECTRICAL DIAGRAM FOR SERIAL FURNACE VIA MOTOR REQUIRES 1 RELAY 51035 WITH 1 JUNCTION BOX NOT INCLUDED ...
Страница 63: ...63 20 GENERAL ELECTRICAL DIAGRAM STANDALONE FURNACE ...
Страница 64: ...64 21 ELECTRICAL DIAGRAM FOR PARALLEL FURNACE ...
Страница 65: ...65 22 ELECTRICAL DIAGRAM FOR ELECTRIC UNIT ...
Страница 78: ...78 31 ELECTRICAL DIAGRAM BECKETT OIL UNIT ...
Страница 79: ...79 32 ELECTRICAL DIAGRAM RIELLO OIL UNIT ...
Страница 81: ...81 33 4 AIR CONDITIONNING DAMPER 33 5 HUMIDIFIER 33 6 HEAT PUMP ...
Страница 82: ...82 34 EXPLODED VIEW AND PART LIST ...
Страница 83: ...83 ...
Страница 84: ...84 ...
Страница 85: ...85 ...
Страница 86: ...86 ...
Страница 87: ...87 ...
Страница 88: ...88 ...
Страница 89: ...89 ...