Technical Data
Technical Data
BOY III Solo / Combi
Width / Height / Depth
mm
395 / 650 / 295
Weight
kg
35
CE- number
CE- 0045BRKD 1002
Type of unit (licensed for...)
B 23 & C 63x
Preset gas type
natural gas type LL
Rated heating range of performance 50/30°C
kW
5,1- 22,8
Rated heating range of performance 80/60°C
kW
4,6 - 20,1
Rated heating load
kW
4,8 - 21,8
Degree of efficiency 50°/30°C
%
106,3
Max. capacity in warm water mode
kW
24
Continuous output of warm water
L/ min
9,8
Adjustment range for warm-up temperature
°C
30
Permitted operational temperature
°C
90
Permitted operational pressure
bar
3
Residual supply pressure
Pa
100
Unit water capacity
L
3,5
Emissions connection
mm
80/125
Emissions material
PPs bis 120°C
Emissions output
oben
HV / HR connection
AG ¾“ flat sealing
Gas connection
IG ½“ flat sealing
Natural gas connection pressure
mbar
20
Liquid gas connection pressure
mbar
50
Electrical connection
V/Hz
230/50
Emission Values
Partial Load
Full Load
Emissions mass flow rate
80/60 °C
g/s
1,87
7,98
Emissions temperature
80/60 °C
°C
68
76
Residual headroom for air and
emissions system
80/60 °C
Pa
100
100
Emissions mass flow rate
50/30 °C
g/s
1,87
7,98
Emissions temperature
50/30 °C
°C
68
76
Residual headroom for air and
emissions system
50/30 °C
Pa
100
100
Natural gas CO
2
-content
Vol.%
9,5
9,5
Liquid propane CO
2
-content
Vol. %
10,0
10,3