Operating the Controls
Operating the Controls
6.3.5.2 Anti-Cycling Drinking-Water Heater
When the demand for drinking-water is over, the anti-cycling function is activated.
When in this mode, the following information will be displayed
Display
Display Element
Drinking-Water Temperature
Segment B and C
Celsius-Symbol
Segment D
Drinking-Water Heater Anti-Cycling
LED 5 = Blinking
blinking
When the heating demand is over, no new heating demands will go through the unit
for 90 seconds. This function lengthens the boiler’s life-span.
6.3.6 Changing the Set-point
6.3.6.1 Changing the Set-point for Central Heating
The set-point for heater water can be changed with
the 4 and 5 buttons. When the heating water set-
point is changed, the following information will be
displayed.
4
5
T
a
s
t e
T
a
s
t e
L
E
D
4
Display
Display Element
Set-point, Central Heating
Segment B and C
blinking
Celsius-Symbol
Segment D
If the value is not changed within 5 Seconds, the display returns to the previous
mode and the new set-point will be saved.
6.3.6.2 Changing the Set-point for the Drinking-Water Heater
The set-point for the drinking-water heater can be
changed with the 6 and 7 buttons. When the drink-
ing-water set-point is changed, the following inform-
ation will be displayed.
6
7
L
E
D
5
T
a
s
t e
T
a
s
t e
Display
Display Element
Set-point, Central Heating
Segment B and C
blinking
Celsius-Symbol
Segment D
If the value is not changed within 5 Seconds, the display returns to the previous
mode and the new set-point will be saved.