INSTALLATION INSTRUCTIONS
Before
working on pipe work, plug the ends to prevent the entry of debris. Decide upon the
route for the gas and lay pipes as required. Where pipes pass through walls they must be
sleeved.
Before
connecting any pipes to the appliance, fully purge pipes of debris or swarf etc. and
connect the gas supply to the 8mm elbow on the fire. Leak test the supply using an approved
method. Fires can be connected to the supply using semi rigid pipe i.e. copper tube also
independently certified, hand bendable corrugated stainless steel connection pipe (such as
Forma Pipe ™) may be used with this appliance
Note: An isolating valve must be situated near the appliance for servicing.
Trim securing screws
Outlet grille (do not obstruct)
Mounting key slots
Gas inlet hole
Inlet grilles (do not obstruct)
Control Opening