background image

Page 10 of 20 

9.5 

Battery Replacement

 

Handset 

On  the  back  of  the  handset  remove  the  battery  cover  by  pressing  down  the  top  of  the 
cover & sliding it down. Remove & unclip the old battery & replace with a new PP3 9 volt 
battery.

 

Receiver Unit (located on your right hand side behind the trim)

  

Switch the battery isolator switch to the (O) position. Lift the unit from its carrier carefully 
noting the pathway of the associated wiring. Remove the top cover, remove old batteries 
& replace with four new AA batteries ensuring the polarities are correct. Replace the 
battery cover & return the receiver unit to its original position. Switch the battery isolator 
switch back to the (I) position. 

Press here and 
slide down

 

 

 

CAUTION:

  With  the  exception  of  battery  replacement  the  receiver  must  be 

located in the carrier 

at all times

.

 

 

 

 

9.6 

Pairing Handset to Receiver 

If for some reason the remote handset requires re-programming to operate the receiver 
follow the procedure below: 

1.

 

Press and hold, using a pointed object, the receiver’s reset button until you hear two 
acoustic signals.  

2.

 

After  the  second  longer  acoustic  signal,  release  the  reset  button  and  within  the 
subsequent 20 seconds, press the  (small flame) on the remote handset until you hear 
an additional long acoustic signal confirming the new code is set. 

 

RESET

 

DUE  TO  THE  SENSITIVE  NATURE  OF  THE  PILOT,  IT  IS  NOT  UNUSUAL  FOR  THE  PILOT  TO 
EXTINGUISH UP TO/AFTER 1 MINUTE WHEN FIRST LIT. RE-LIGHT AND THE PILOT WILL STAY 
ALIGHT. 

 

Содержание LONGITUDE

Страница 1: ...Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4530 39InstUser G20 G31 March 2019 TO OBTAIN...

Страница 2: ...valve Elbow 82 340 Elbow 92 160 Pilot SIT 9116 Seagas P451 Average measured NO2 room 119ppb 115 1ppb The inlet pressure must be within 1mBar of specification with all gas appliances in the house switc...

Страница 3: ...o convert cubic feet ft to cubic metre m divide the room volume in cubic feet by 35 3 3 6 The heater must not be installed in high rise blocks of flats unless a gas supply already exists bed sitting r...

Страница 4: ...connect the gas supply to the 8mm elbow on the fire Leak test the supply using an approved method Fires can be connected to the supply using semi rigid pipe i e copper tube also independently certifi...

Страница 5: ...on on the back of the appliance The top of the flue should also be capped off to prevent the entry of moisture etc consult building control if in any doubt 5 CLEARANCES TO COMBUSTIBLE MATERIALS AND SH...

Страница 6: ...hrough walls seal the pipe ends to prevent debris entering the pipes 6 5 The fire must be mounted minimum 200mm from floor level 6 6 Hang the appliance on the wall and fix into position 6 7 Fully purg...

Страница 7: ...on the gas access cover to the O position Undo the securing screw for the receiver holder on the right hand side of the appliance as shown below Pilot Burner Burner Outlet Battery Switch Battery Swit...

Страница 8: ...gas access cover is in the O position fit four AA 1 5V batteries into the receiver unit Fit the PP3 9V battery into the transmitter hand set Press the battery switch located on the underside of the g...

Страница 9: ...lit the igniter will stop another acoustic signal will confirm the pilot has been established if the pilot fails to establish repeat the process Due to the safe efficient nature of the fire it is not...

Страница 10: ...tery isolator switch back to the I position Press here and slide down CAUTION With the exception of battery replacement the receiver must be located in the carrier at all times 9 6 Pairing Handset to...

Страница 11: ...ine BEFORE you leave the installation If the appliance is not fitted in strict accordance with these instructions Burley cannot be held responsible for any damage caused and reserve the right to charg...

Страница 12: ...laced the original manufacturer s parts must be used Controls The GAS CONTROL IS FACTORY SET AND NORMALLY NEEDS NO ADJUSTMENT Check for smooth operation of the gas valve Remove access cover check the...

Страница 13: ...ings CHIP1000 900g CHIP1000 900g Glass GLA4530 GLA4530 USE ONLY GENUINE REPLACEMENT PARTS Parts ordered from our factory will normally take 5 7 working days to be delivered An Express service is avail...

Страница 14: ...be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on full for at least 15 mins There a...

Страница 15: ...e consult the relevant manufacturer Only use replacement catalyst supplied by Burley If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air...

Страница 16: ...r a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncertainties can creep in It is worth measuring...

Страница 17: ...rmerly CORGI within the first year as with all gas products every gas appliances must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other...

Страница 18: ...recycling WEEE Dispose of electrical equipment in an environmentally correct manner When disposing components containing Refractory Ceramic Fibres RCF we recommend that the items are not broken up bu...

Страница 19: ...Page 19 of 20...

Страница 20: ...iglo fires are protected by UK patents 2193802 2240620 and 2256920 Other Patents Pending Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Tel 01572 725570 Fax 01572 724390 www burley co uk...

Отзывы: