COMMISSIONING
10.1
TEST THE GAS PRESSURE
. Turn the fire on full, attach a manometer to the inlet test point
and ensure there is a pressure of 20mbar (+/- 1mbar) for natural gas appliances or
37mbar for propane appliances. Now turn on every other gas appliance in the house and
re-check the pressure. The pressure must still be within the tolerance of +/- 1mbar. Now
turn off all the other gas appliances and turn the fire down to pilot only, the pressure
must still be within the tolerance of +/- 1mbar. If it is not TRANSCO, BORD GAIS or the gas
supplier must be called to adjust the governor to the house before the fire can be
commissioned further.
Call outs to fires with incorrect pressures will be chargeable.
10.2
Brief the customer on the operation of the appliance and give them all the instructions.
The customer must be told of the need for regular servicing of the appliance, this will be
at least once a year and be made aware that no rubbish is to be thrown onto the fire bed.
The customer must also be made aware that purpose provided ventilation should be
checked regularly and not be blocked.
10.3
If you have any questions or the fire is not operating correctly, phone the Burley help-
line BEFORE you leave the installation.
If the appliance is not fitted in strict accordance with these instructions, Burley cannot
be held responsible for any damage caused and reserve the right to charge for any
corrective work. Double check standing and working pressures and securely seal all
relevant open chimneys and flues.
10.4
Oxygen Depletion Pilot System
There is a highly sensitive oxygen depletion sensor
designed into the pilot light and may not light first time or may extinguish after a few
minutes, please advise the customer of this. If any part of the OXY Pilot is damaged the
entire unit must be replaced. Do not attempt to bend or alter the flame head,
thermocouple or aeration hole. Use only genuine spare parts as similar looking parts from
other appliances may well give different or inferior performance and could lead to a
hazard.
10.5
Fireguards
A fireguard is not supplied with this appliance and being wall mounted, the
need for one will have to be assessed depending on the position, height from ground of
the fire; however it is recommended that a fireguard to BS8423 is fitted if the fire is to be
used in the presence of young children, the elderly and the infirm.
10.6
Completion of Warranty Card. The installer section of the guarantee card must be filled
in fully to validate the warranty. I.e. pressure, model, room size and Gas Safe™
registered installer (formerly CORGI) number