background image

Page 9 of 20 

9

 

Lighting the Appliance 

Ensure  that  the  battery  ON/OFF  switch  located  on  the  receiver  holder  is  in  the  ON 
position  (I)  &  that  the  MAN/ON  selection  knob  is  also  pointing  upwards  towards  its  ON 
position (see below). 

 

 

 

 

Simultaneously press and hold the   (red circle) and  (large flame) buttons until an 
acoustic signal confirms the start sequence has begun, then release the buttons.

 

 

Press 
these two 
buttons 
together to 
light the 
burner 

Once lit 
use this 
button to 
increase 
gas rate

Once lit 

use this 
button to 
decrease 
gas rate

 

9.1 

The  acoustic  signal  should  cease  and  be  replaced  with  the  ticking  sound  of  the  spark 
igniter.  When  the  pilot  flame  is  lit  the  igniter  will  stop  &  another  acoustic  signal  will 
confirm  the  pilot  has  been  established  (if  the  pilot  fails  to  establish  repeat  the  process. 
Due to the safe & efficient nature of the fire it is not unusual for this to take two or even 
three  attempts).  The  acoustic  signal  will  now  cease  &  the  gas  rate  adjusting  knob  will 
automatically turn to its high setting. 

9.2 

To adjust the gas rate to desired setting press the  (large flame) to increase the flame 
height or  (small flame) to decrease the flame height on the handset. 

9.3 

To leave the fire in 

standby mode

 press the  (small flame) until the main burner goes out. 

The pilot should remain on in this mode & help to reduce condensation.  

9.4 

To turn the fire off

 completely (including the pilot) press the   red OFF button on the 

handset. 

Gas rate adjusting knob 

Remote ON 
selector 

 

Remote Control Gas Valve 

Содержание LONGITUDE

Страница 1: ...Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4530 39InstUser G20 G31 March 2019 TO OBTAIN...

Страница 2: ...valve Elbow 82 340 Elbow 92 160 Pilot SIT 9116 Seagas P451 Average measured NO2 room 119ppb 115 1ppb The inlet pressure must be within 1mBar of specification with all gas appliances in the house switc...

Страница 3: ...o convert cubic feet ft to cubic metre m divide the room volume in cubic feet by 35 3 3 6 The heater must not be installed in high rise blocks of flats unless a gas supply already exists bed sitting r...

Страница 4: ...connect the gas supply to the 8mm elbow on the fire Leak test the supply using an approved method Fires can be connected to the supply using semi rigid pipe i e copper tube also independently certifi...

Страница 5: ...on on the back of the appliance The top of the flue should also be capped off to prevent the entry of moisture etc consult building control if in any doubt 5 CLEARANCES TO COMBUSTIBLE MATERIALS AND SH...

Страница 6: ...hrough walls seal the pipe ends to prevent debris entering the pipes 6 5 The fire must be mounted minimum 200mm from floor level 6 6 Hang the appliance on the wall and fix into position 6 7 Fully purg...

Страница 7: ...on the gas access cover to the O position Undo the securing screw for the receiver holder on the right hand side of the appliance as shown below Pilot Burner Burner Outlet Battery Switch Battery Swit...

Страница 8: ...gas access cover is in the O position fit four AA 1 5V batteries into the receiver unit Fit the PP3 9V battery into the transmitter hand set Press the battery switch located on the underside of the g...

Страница 9: ...lit the igniter will stop another acoustic signal will confirm the pilot has been established if the pilot fails to establish repeat the process Due to the safe efficient nature of the fire it is not...

Страница 10: ...tery isolator switch back to the I position Press here and slide down CAUTION With the exception of battery replacement the receiver must be located in the carrier at all times 9 6 Pairing Handset to...

Страница 11: ...ine BEFORE you leave the installation If the appliance is not fitted in strict accordance with these instructions Burley cannot be held responsible for any damage caused and reserve the right to charg...

Страница 12: ...laced the original manufacturer s parts must be used Controls The GAS CONTROL IS FACTORY SET AND NORMALLY NEEDS NO ADJUSTMENT Check for smooth operation of the gas valve Remove access cover check the...

Страница 13: ...ings CHIP1000 900g CHIP1000 900g Glass GLA4530 GLA4530 USE ONLY GENUINE REPLACEMENT PARTS Parts ordered from our factory will normally take 5 7 working days to be delivered An Express service is avail...

Страница 14: ...be carried out in accordance with BS5871 Pt 4 The catalytic converter needs heat to work therefore before you start testing the fire must have been lit and burning on full for at least 15 mins There a...

Страница 15: ...e consult the relevant manufacturer Only use replacement catalyst supplied by Burley If you or the customer detects any odours from the fire please remember that the catalytic convertor is not an air...

Страница 16: ...r a reasonable period of time so that the capacity of the meter is used On low Input appliances such as our flueless this is even more critical because uncertainties can creep in It is worth measuring...

Страница 17: ...rmerly CORGI within the first year as with all gas products every gas appliances must be serviced every year The appliance has not been subject to misuse accident or repaired or fitted by anyone other...

Страница 18: ...recycling WEEE Dispose of electrical equipment in an environmentally correct manner When disposing components containing Refractory Ceramic Fibres RCF we recommend that the items are not broken up bu...

Страница 19: ...Page 19 of 20...

Страница 20: ...iglo fires are protected by UK patents 2193802 2240620 and 2256920 Other Patents Pending Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Tel 01572 725570 Fax 01572 724390 www burley co uk...

Отзывы: