Page 2 of 20
INTRODUCTION
Thank you for choosing this Burley product. All of our products carry a CE mark which is awarded
by an independent test house (notified body) and shows the fires have been type tested to meet
the essential requirements of the European Gas Appliance Regulations and the appropriate
British Standards.
Efficiency Declaration
This appliance has a thermal efficiency of 100% giving an Energy Efficiency Index of 91%. Which is
A
rated on all variants & emits less than 130mg/kWh NOx.
Declaration of Conformity
Burley Appliances declare that the appliance described in “Technical data” conforms to the
following standard(s) BS EN14829:2007
Please demonstrate the appliance method of operation to the customer before leaving.
An oxygen depletion sensing pilot light is fitted and will sense any significant oxygen depletion in
the room and shut the fire down safely.
1.
TECHNICAL DATA
Refer to the appliance data badge affixed to the gas access cover (page 5).
ENSURE THAT THE LOCAL CONDITIONS OF USE CORRESPOND TO THE DATA ON THE BADGE
Natural Gas G20
Propane G31
Category
I2H
I3P
Supply Pressure
20mbar
37mBar
Inlet Pressure
20mbar
*
37mBar
Heat Input (net)
(High)
4.2kW
4.2kW
(Low)
2.5kW
3.0kW
Inlet Connection
8mm Compression
Injector (manual valve)
Elbow 82/340
Elbow 92/160
Pilot
SIT 9116
Seagas P451
Average measured NO2 (room)
119ppb
115.1ppb
*
The inlet pressure must be
/- 1mBar
of specification with
all
gas appliances in the house
switched on
and also
with just the Burley heater operating. If outside of this tolerance the fault is
most likely to be in the installation pipe work or service governor at the meter. If the problem is
the meter governor, this is the property of the gas service provider (such as Transco / National
Grid 0800 111999 or Bord Gais) and they should be called to rectify this. The fire will not operate
correctly if the pressures are incorrect.
2.
UNPACKING THE APPLIANCE
2.1
Carefully examine the carton for damage before unpacking. If it is obviously damaged,
consult the supplier as to whether to proceed with the installation.
2.2
Make sure the carton is stood upright and open the top.
2.3
Remove the fittings boxes contained within and open them and check the condition of the
contents. Remove the fire and examine its general condition, paying particular attention
to the frame, the glass front and fire box flanges.
2.4
If satisfied by the general condition, place the decorative components to one side and
proceed with the installation. If in any doubt, seek advice from the supplier.
Read these
instructions fully before proceeding even if you have fitted this model before.
THE APPLIANCE IS NOT TO BE RECESSED INTO THE WALL FOR SAFETY AND OPERATIONAL REASONS
Содержание LONGITUDE
Страница 19: ...Page 19 of 20...