Page 29
29877 121302
P2608
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
CALIBRATE FLOW
This function allows the operator to enter the
actual flow rate of the sprayhead and the bypass for
each side of the brewer by dispensing both separately
for one minute. The volumes are then entered in
ounces per minute (OZ/M).
Procedures to calibrate the sprayhead flow rate:
1. Place a container, accurately graduated in ounces,
and with a minimum capacity of 60 ounces, be-
neath the funnel on the side of the brewer to be
calibrated.
2. Press and hold the ® pad until the display reads
SET NEW RECIPES
. Release the ® pad. Press and
release the ® pad until the display reads
CALI-
BRATE FLOW ?
.
3. Press and release
YES
to advance to the
SPRAY
HEAD CAL?
function screen. (Pressing
NO
in the
CALIBRATE FLOW
screen will advance to the next
function screen,
BREW COUNTERS).
4. Press and release the
YES
pad. The display should
read
CONTAINER READY?
If the container is un-
der the funnel, press
YES.
The display should read
CALIBRATE SPRAY .. PRESS BREW TO START.
5. Press and release the
pad on the side to be
calibrated. The display should read
CALIBRATE
SPRAY .. 60 SEC TO FINISH.
The 60 second timer
on the display will count down to zero. When the
counter reaches zero, the display will change to
LEFT
or
RIGHT OZ.,
along with a number signify-
ing ounces per minute.
6. Measure the amount of water in the container and
using the
(-)
or
(+)
pads, adjust the amount on the
display to match the amount in the container. Then
press
DONE
.
7. The display should now read
NEW L
or
R SPRY
FLOW
, along with the correct flow rate of the
sprayhead in ounces per minute. After about 5
seconds, the display will return to the
CALIBRATE
FLOW
screen.
8. To exit the
CALIBRATE FLOW
program, press
NO
to advance to the next function screen, or press
and release the
pad located on the front
switch panel to exit the
CALIBRATE FLOW
func-
tion and return to the
MAIN SCREEN.
9. Repeat steps 1 - 8 when calibrating the other side.
LEFT OZ XX.X
NEW L SPRY FLOW
XX.X OZ/M
Left or Right
L or R