Page 19
29877 080301
PROGRAMMING FUNCTIONS - LEVEL 2 (cont.)
% BYPASS
This function allows adjustment of the amount of
water that bypasses the grounds. The number signi-
fies the percentage of the brew volume which does not
flow over the coffee grounds.
Modifying recipes - bypass percentages:
Range: 0% to 90% for all three batch sizes
NOTE:
If the brewer is already in the
% BYPASS
screen, it is not necessary to follow steps 1 through 6
in this section, but proceed directly to step 7.
1. Press and hold the ® pad until the display reads
SET NEW RECIPES.
Release the ® pad. Press the
® until the display reads
REVIEW RECIPES
.
2. Press
YES
to proceed. The display should now
read
NO-NAME LEFT,
along with
MODIFY, SHOW
and
NEXT.
3. Press and release
NEXT
to advance to the desired
coffee name to be modified.
P2292
4. Press and release
MODIFY.
The display should
read
BREW OZ.
5. Press and release
DONE
. The display should read
3 BATCHES DONE?
.
6. Press and release
YES
. The display should now
read
% BYPASS
, and a batch light will be blinking.
Press and release the batch size to be modified.
7. Using
(-)
and
(+)
set the amount of bypass water
(percentage) to be dispensed
around
the grounds
for that particular batch size.
8. When finished, press another batch size and re-
peat step #7 for each batch to be modified.
9. When finished setting all batch sizes, press
DONE
.
The display should read
3 BATCHES DONE?
10. If they are not correct, press and release
NO
to
return to the
% BYPASS
setup screen.
11. If the 3 batch sizes are correct, press
YES
. This will
advance to
SET PULSE BREW
. Another alternative
is to press either of the
pads to exit the
%
BYPASS
setup and return to the
MAIN SCREEN.