Notes:
• When you cancel failover settings, attributes of the shared folders on the backup TeraStation will become read-
only. Change the attribute settings to the desired options if necessary.
• If replication is configured for more than one folder, initialize the TeraStation before configuring failover.
• The main TeraStation cannot be used as the backup location for Time Machine.
• Do not use the same TeraStation for both failover and replication, or failover and Time Machine.
• If email notification is enabled and failover occurs, navigate to
Management
>
Email Notification
>
Edit
in the main
TeraStation’s Settings and click
OK
.
• Ethernet frame size settings for main and backup TeraStations should be 1500 bytes. To change the Ethernet
frame size, navigate to
Network
>
IP Address
, click the LAN port and
Edit
, and change the Ethernet frame size to
“1500” bytes.
• Files whose filenames contain more than 80 alphanumeric characters will not be backed up.
• If the I33 message appears on the LCD panel, navigate to
Backup
>
Replication
and click
Resync
.
Replacing to the Backup TeraStation Manually
If “Switch to backup unit manually” is selected on the
Advanced Settings
tab in the main TeraStation’s Settings, the
backup TeraStation will not replace the main TeraStation if the main TeraStation fails. To have the backup TeraStation
replace the main TeraStation, you can either:
• Log in to Settings for the backup TeraStation and click
Set as Main Unit
.
• Or, press and hold the function button on the backup TeraStation.
Note:
If the main TeraStation fails but both LAN ports’ link on the backup TeraStation is up, the backup TeraStation
cannot replace to the main TeraStation from Settings. In such a case, use the function button instead.
Reconfiguring After Failover Occurs
When the backup TeraStation replaces the main TeraStation, the I49 message may appear on the backup
TeraStation’s LCD panel and NAS Navigator2. To configure failover again, follow the procedure below using the new
TeraStation unit. The following procedure is an example using the replaced backup TeraStation (“main TeraStation”)
and the new TeraStation (“backup TeraStation”).
If you don’t want to configure failover with the new TeraStation, cancel the failover settings by following the steps
1–5 below and restart both TeraStations. The I49 message will disappear.
Note:
The following procedure will also work if failover occurs unexpectedly.
1
After failover occurs, log in to Settings for the main TeraStation.
If you have configured to sync with the UPS device connected to the failed TeraStation, the E10 message will
appear on the main TeraStation. In such a case, follow the procedure below to change the UPS settings on the
main TeraStation. If you didn’t, skip to the next step.
(1) Disconnect the UPS cable from the failed TeraStation and connect it to the main TeraStation.
(2) Click
Management
.
(3) Click
to the right of “UPS Sync”.
(4) Click
Edit
.
(5) Select “Sync with UPS connected to this TeraStation” and reconfigure the desired UPS settings.
(6) Click
OK
when finished.
2
Click
Backup
.
102
Содержание terastation 3000
Страница 23: ...4 Configure the desired settings then click OK 22...
Страница 26: ...3 Click Create User 25...
Страница 29: ...3 Click Add Group 28...
Страница 109: ...6 Click Time Machine 108...
Страница 110: ...7 Click Select Backup Disk 8 Select the shared folder and click Use Disk 109...
Страница 128: ...3 Click Edit 4 Click Browse 5 Select the shared folder that you want to make available to iTunes then click OK 127...
Страница 129: ...6 Click OK then OK again 7 Move the iTunes server switch to the position to enable the iTunes server 128...
Страница 134: ...4 Open the License tab then click Activate Free License To deactivate the license click 133...
Страница 136: ...3 Click Next 4 Click Find Cameras 135...
Страница 142: ...2 Select the search criteria on the left side of the search screen then click Search 141...
Страница 143: ...3 The search results are displayed Click a thumbnail to start the media viewer 142...
Страница 161: ...14Check that the license pack was added to Installed Licenses This completes authentication of an additional license 160...
Страница 187: ...9 Click the Client Settings tab 186...
Страница 191: ...4 Click Edit Note The settings of the PHP language interpreter can be changed from Edit php ini 5 Click Browse 190...
Страница 209: ...3 Click the LAN port where the jumbo frames will be used 4 Select the desired Ethernet frame size and click OK 208...