manualshive.com logo in svg
background image

05/02 - PC

335818

Part. T5843A/GB

Installer instructions
for use

Te

rraneo

Telephone exchange

P

ABX 18D

Содержание Terraneo PABX 18D

Страница 1: ...05 02 PC 335818 Part T5843A GB Installer instructions for use Terraneo Telephone exchange PABX 18D ...

Страница 2: ...e light Self switch on outdoor station Temporary unlock of locked prefixes Activate fast line for data transmission Activating a relay Deactivating a relay Night service Return to day service Audio room monitor Call capture with answering machine R da 401 a 408 R 400 telephone number R55 R 30 short number from 01 to 50 R 50 lift the receiver R R from 401 to 408 and hang up R R7 with Pivot R8 with ...

Страница 3: ...RELAYS pag 17 CALL REPEATER FUNCTION FOR EXTRA BELL pag 18 DISABLING TELEPHONES FROM RECEIVING INCOMING TELEPHONE CALLS pag 19 DISABLING TELEPHONES FROM MAKING OUTGOING TELEPHONE CALLS pag 20 DISABLING TELEPHONES FROM RECEIVING DOOR ENTRY CALLS pag 21 DISABLING TELEPHONES FROM PERFORMING DOOR ENTRY SERVICES pag 22 5 PROGRAMMATION THE TYPE APPLICATIONS USING THE TYPE APPLICATIONS pag 23 EXAMPLES OF...

Страница 4: ...ARRIERS pag 43 PREFIXES TO BE UNLOCKED FOR OTHER CARRIERS pag 44 EXAMPLES OF ACTIVATION OF LOCKS ON OUTGOING DIALLING pag 45 9 INSTALLATION CABLES AND CONNECTIONS pag 53 INSTALLING PABX EXCHANGE pag 53 COMPOSITION OF THE TELEPHONES VIDEO SECTION pag 54 INSTALLING THE TELEPHONE WALL MOUNTED VIDEO SECTION pag 55 INSTALLING THE TELEPHONE TABLE MOUNTED VIDEO SECTION pag 55 CONNECTION DIAGRAMS pag 56 S...

Страница 5: ...es radiators stoves cookers Do not install the exchange in places which are very dusty or where there are corrosive vapours Room temperature from 0 to 40 C relative humidity from 20 to 80 not condensing When the installation is complete perform the following operations 1 Perform all the tests described in section 9 7 SYSTEM TYPE APPROVAL carefully 2 Check all the functions described in the MAIN FU...

Страница 6: ...gency telephone line 1 and possibility of fast line programming for fax or modem PC connector for exchange programming Connector for back up battery function not available Green led 230 V a c ON Analog telephone line Earth terminal to protect telephone lines inside the exchange Red led to check correct operation Speaker unit of the door entry system or riser interface connection by interface of th...

Страница 7: ...35916 extra devices can be operated e g opening the driveway gate or other The Distributor and video Expander accessories can connect up to 8 video door entry telephones as an alternative to the 8 telephones which can be directly connected to the exchange 3 outdoor video door entry stations and a surveillance camera offering great simplification in making the system Because of its ease of use and ...

Страница 8: ...ch prevents programming by unauthorised persons is saved permanently until the user changes it again Personalisation is not possible with pulse dial telephones 2 3 MUSIC WHILE ON HOLD The exchange is already programmed with music while on hold containing the message please hold the line Any outside musical source can be used as an alternative to this see section 2 7 2 4 HOUSE AUTOMATION SCENARIOS ...

Страница 9: ...NS EXAMPLE OF A SYSTEM WITH TWO DOOR ENTRY CALLS Door entry call 1 Door entry call 2 Home door entry call 2 Office door entry call 1 Telephone system 2 5 DOOR ENTRY CALLS The telephone exchange can manage up to 2 separate door entry calls which can be addressed separately on 2 telephone units If activated the DOSA service can put through a door entry call from an outdoor station to a telephone num...

Страница 10: ...ivated both by the telephone key STAIRCASE LIGHT or by the speaker unit staircase light key Switching on from the outdoor station can however be disabled by programming see the Assigning a relay to the staircase light pushbutton of the outdoor station section 2 9 CALL REPEATER FOR EXTRA BELL This function can command a relay when a telephone receives a call from outside telephone line door entry u...

Страница 11: ...e mode for 2 seconds The relay can be used for other services instead of switching on the staircase light by means of specific programming 3 2 PROGRAMMING FUNCTIONS BY PERSONAL COMPUTER All the functions can be programmed by Personal Computer for this type of programming the exchange must be connected with a PC by means of interface item 335919 The interface is made up of a 1 5 m multi cable with ...

Страница 12: ...T To reset the factory values for some or whole groups of parameters use the following commands after performing the access programming procedure general reset wait for the confirmation tone Warning The command modifies the Password returning it to the initial value 1 2 3 4 and cancels the short number table the programmed locks tables and the carrier table For the other setting see the descriptio...

Страница 13: ...h tone telephones The programming is valid for all the telephones Programming to deactivate direct access 1 lift the receiver 2 press the R key wait for the start dialling tone 3 dial 980 4 dial the password 4 numbers and wait for the dial tone 5 dial 10 to deactivate the service 6 confirm by pressing the R key 7 after receiving the confirmation tone hang up Programming to activate direct access 1...

Страница 14: ...AMMING TYPE OF OUTSIDE TELEPHONE LINE This must be performed when the two lines are pulse dial or when only one of the two telephone lines is used The commands must be performed after the programming access procedures see section 3 4 Example activating the telephone line as pulse dial Lift the receiver Press the R key you will hear the start dialling tone Type Dial the password e g base 1 2 3 4 Af...

Страница 15: ...automation scenarios chapter 4 SIMPLIFIED PROGRAMMING 0 0 73 Type of device on 401 Type of device on 402 Enter for each type of device 0 Telephone 1 Answering machine 2 Fax 3 Modem 4 Answering machine Fax 5 Modem Fax 6 Answering machine Modem Fax 9 Does not change the previous programming Example telephone on extension 401 and fax on extension 402 Lift the receiver Press the R key you will hear th...

Страница 16: ...tomation scenarios Example line 1 enabled for remote operation 74 0 0 0 0 Telephone line 1 0 Not enabled 4 Remote operation 5 Recognition Fax or Modem tone 9 Does not change the previous programming Lift the receiver Press the R key you will hear the start dialling tone Type Dial the password e g base 1 2 3 4 After the start dialling tone type the Macrocommand 7 4 4 0 0 0 After hearing the confirm...

Страница 17: ...ted 3 minutes 2 remotely operated On Off 3 not remotely operated 2 seconds 4 not remotely operated 3 minutes 5 not remotely operated On Off 6 Staircase light 2 seconds 7 Staircase light 3 minutes from 0 to 8 0 exchange relay 1 relay 1 on module 1 2 relay 2 on module 1 3 relay 3 on module 1 4 relay 4 on module 1 5 relay 1 on module 2 6 relay 2 on module 2 7 relay 3 on module 2 8 relay 4 on module 2...

Страница 18: ...1 401 telephone 1 2 relay 2 402 telephone 2 3 relay 3 403 telephone 3 4 relay 4 404 telephone 4 5 relay 5 405 telephone 5 6 relay 6 406 telephone 6 7 relay 7 407 telephone 7 8 relay 8 408 telephone 8 from 0 to 8 Example extra bell connected to relay 3 associated with extension 403 Lift the receiver Press the R key you will hear the start dialling tone Type Dial the password e g base 1 2 3 4 After ...

Страница 19: ...line The personalisation procedure is the following 5 5 1 1 01 01 3 3 0 1 Line 1 0 0 0 0 0 0 Telephone number from01to08 Disabling telephone 1 Reenabling telephone 1 Lift the receiver Press the R key you will hear the start dialling tone Type Dial the password e g base 1 2 3 4 After the start dialling tone type the Macrocommand After hearing the confirmation tone 3 short tones hang up Link with ho...

Страница 20: ...se the outside telephone line to make outgoing calls In basic programming conditions all the extensions are enabled to use the outside line The personalisation procedure is the following Example disabling telephone 04 from making outgoing telephone calls 0 4 2 5 0 0 0 0 1 5 5 1 1 01 01 2 2 0 1 0 0 0 0 0 0 Line 1 Telephone number from01to08 Disabling telephone 1 Reenabling telephone 1 Link with hou...

Страница 21: ...one number from0to16 0 0 1 2 Enabling to the call from only pushbutton 1 5 1 01 0 3 5 1 01 0 0 Enabling to the call from only pushbutton 1 Disabling telephone 1 Reenabling telephone 1 Example disabling telephone 8 for video door entry calls 0 8 0 5 3 1 Lift the receiver Press the R key you will hear the start dialling tone Type Dial the password e g base 1 2 3 4 After the start dialling tone type ...

Страница 22: ...pen the electric door lock switch on the staircase lights or auto switch on the outdoor station door entry services In basic programming conditions all the telephones can perform the door entry services The personalisation procedure is the following 5 5 1 1 01 01 0 1 2 2 Telephone number from0to16 Disabling telephone 1 Reenabling telephone 1 Example disabling telephone 04 0 4 5 1 0 2 Link with hou...

Страница 23: ...grammed as remotely operative Answering machine management To select the type application Where XX is the code to set to call the type application Note after this programming there is no need to switch off the power to the exchange Type applications 76 xx XX Type applications 00 Management of fax and modem example 1 sect 5 2 01 Relay 1 programmed as remotely operative from outside telephone line e...

Страница 24: ...mple 3 of the following chapter Note after the following programming there is no need to switch off the power to the exchange 1 2 3 4 7 6 0 2 R Lift the receiver After hearing the confirmation tone hang up wait for about 40 seconds Type the command corresponding to the type application required Dial the password base1234 Type Wait for the start dialling tone Press the key you will hear the start d...

Страница 25: ...ry calls section remembering that the command only acts on the house automation scenario programmed The automatic recognition of the Fax or Modem tone has been set on the telephone line 74 5999 macrocommand to activate the individual function A modem has been set on extension 401 73 39 macrocommand to activate the individual function a b a b a b FAX PRI C NO 230V 50Hz a b 1 a b 2 a b 3 a b 4 a b 5...

Страница 26: ... 9499 macrocommand to activate the individual function Relay 1 has been programmed for remote activation 75 10 macrocommand to activate the individual function PRI C NO 230V 50Hz a b 1 a b 2 a b 3 a b 4 a b 5 a b 6 a b 7 a b 8 PC 230V 50Hz FAX M P T R a b U1 3 4 6 A 2 A COS 0 5 M AUX EXP 1 T T P M 12V C C 1 2 3 4 IN OUT C C 1 2 3 4 335818 spa Patent Pending 230V 15 50 Hz 0 15 A PABX 18D cod 335818...

Страница 27: ... Example 3 Answering machine type applications The answering machine is programmed on extension 2 The programming is valid for all the house automation scenarios To disable door entry calls on extension 1 refer to the Disabling telephones for door entry calls section remembering that the command only acts on the house automation scenario programmed An answering machine has been set on extension 40...

Страница 28: ...d in this chapter can only be sent to the exchange after performing the programming access procedure described in section 3 3 6 1 PROGRAMMING TELEPHONE LINE TYPE This must be performed when the line is pulse dial Lift the receiver Press the R key you will hear the start dialling tone Type Dial the password e g base 1 2 3 4 If the telephone line is touch tone type If the telephone line is pulse dia...

Страница 29: ...LIGHT FUNCTION The relay inside the exchange is already set up as base as staircase light commanded by the button any other relays item 335916 can however be programmed as staircase light To reset the initial condition for internal relay 0 dial sequence 20004 30 Example to enable relay 3 for the staircase light function with 2 second timing dial 2 0 2 8 3 0 0 200 04 3 0 Relay identification number...

Страница 30: ...y 7 43 relay 8 Z telephone number 0 416 1 401 2 402 3 403 4 404 5 405 6 406 7 407 8 408 Example to associate relay 4 with extension 6 to operate the extra bell dial 2 0 3 1 2 6 0 6 ADVANCED PROGRAMMING XX 200 2 0 1 1 1 Relay identification number see table at the side Disabling Enabling the staircase light button of the outdoor station 0 disabled 1 enabled Outdoor station 0 Outdoor station 1 Outdo...

Страница 31: ...on and establish the timing of the relay inside the exchange and the relays on the extra expansion modules item 335916 The programming on internal relay 0 excludes the Switch staircase light on door entry service and activates the possibility of controlling the internal relay in monostable mode with a command from the keypad To reset the Switch staircase light on function with or R8 on relay 0 dia...

Страница 32: ...ration and establish the timing even from outside telephone line of the relay inside the exchange and the relays on the extra expansion modules item 335916 The programming on internal relay 0 excludes the Switch staircase light on door entry service and activates the possibility of controlling the internal relay in monostable mode with a command from the keypad To reset the Switch staircase light ...

Страница 33: ...respect the command entry sequence 6 10 LENGTH OF THE CALL SIGNAL FROM THE OUTDOOR STATION To reduce the length of the call signal from 30 seconds to 6 seconds 1 Lift the receiver 2 Perform the programming access procedure sect 3 3 3 Dial the sequence 20003 0 4 After receiving the confirmation tone hang up To reset 30 seconds dial the sequence 20003 1 6 11 PROGRAMMING THE OUTSIDE MUSIC SOURCE If a...

Страница 34: ...n activate one of the five programmings for incoming and outgoing calls subdivision into bands for each telephone remote activation recognition of the FAX and MODEM tone door entry services the Dosa service These programmings are defined house automation scenarios Each house automation scenario can be activated by means of one of the following commands 311 312 313 314 or 315 The exchange is suppli...

Страница 35: ...ion The programming and activation commands must be sent to the exchange after performing the programming access procedure sect 3 3 PROGRAMMING The programming occurs with the following command ACTIVATION After performing the programming the services must be activated with the following command Warning The second command modifies the activations of the services on all the local lines the enabling ...

Страница 36: ...ver Perform the programming access procedure Dial Wait for the confirmation tone Dial 7 3 PROGRAMMING WAIT RINGS For remote activation the number of wait rings before answering can be set to allow any answering machines to work if an answering machine has been programmed the exchange can still supply the remote activation service 5 1 5 1 3 2 1 9 0 Telephone line Linkwith scenario311 315 from1to5 N...

Страница 37: ...rm the programming access procedure Dial Note Other extensions can have fax or modem See the Advanced programming chapter Characterisation of an extension section C Disabling FAX or MODEM for door entry calls for house automation scenario 1 Lift the receiver Perform the programming access procedure Dial Wait for the confirmation tone Dial 7 HOUSE AUTOMATION SCENARIO PERSONALISATION 3 0 1 0 0 0 1 0...

Страница 38: ... After 45 seconds of conversation the exchange sends a sound to warn the user that the conversation is about to finish If the user types a number between 0 and 9 the conversation can continue if not it will end after 50 seconds The conversation time can be longer in the following cases Systems with dedicated speaker unit item 335902 connected directly to the telephone exchange Systems with video d...

Страница 39: ...omation scenario 5 on door entry call 1 dial After receiving the confirmation tone 3 quick tones hang up Once programmed the service will be activated with telephone command 315 for house automation scenario 5 Note in the basic exchange configuration this service is deactivated on all the house automation scenarios House automation scenario from 1 to 5 Outdoor station on which the Dosa service wil...

Страница 40: ...password 01 Extension number from 01 to 08 R to lock prefix 00 on telephone 1 The procedure to unlock prefix 00 on telephone 1 is the following 1 Dial the sequence 960 XXXX where XXXX corresponds to the programming password 01 Extension number from 01 to 08 R 2 After receiving the confirmation tone hang up To individually lock the telephone carriers for international calls do not use this lock pre...

Страница 41: ...mation tone and then enter other prefixes maximum 8 repeating operation 5 8 Hang up If a mistake is made when entering the prefix hang up and repeat all the operations starting from 2 To cancel a prefix to be locked proceed as above and in point 5 dial the sequence nn from 01 to 08 R Warning if you want the programmed prefix lock and the international call lock simultaneously enter prefix 00 in th...

Страница 42: ...are the four numbers of the programming password 5 Wait for the dial tone 6 Dial the sequence nn from 01 to 08 YYYY YYYY prefix to unlock R 7 Wait for the confirmation tone and then enter other prefixes maximum 8 repeating operation 5 8 Hang up If a mistake is made when entering the prefix hang up and repeat all the operations starting from 2 To cancel a prefix to be unlocked proceed as above and ...

Страница 43: ... of the programming password 5 Wait for the dial tone 6 Dial the sequence nn from 01 to 05 YYYYYY carrier prefix from 4 to 6 numbers R 7 Wait for the confirmation tone and then enter other carrier prefixes maximum 5 repeating operation 5 8 Hang up If a mistake is made when entering the carrier prefix hang up and repeat all the operations starting from 2 To cancel a carrier prefix proceed as above ...

Страница 44: ... enter other prefixes to be unlocked maximum 3 repeating operation 5 8 Hang up Proceed in the same way to unlock the prefixes for other carriers dialling the sequences 382 XXXX for carrier 02 383 XXXX for carrier 03 384 XXXX for carrier 04 385 XXXX for carrier 05 If for one or more carriers you want to unlock the prefixes already defined in the Telecom carrier table in point 4 dial the sequence 01...

Страница 45: ...table 4 Define the telephone prefixes to be unlocked for each carrier and make a note of them in the table EXAMPLE 1 Lock long distance calls with just one carrier Telecom A Fill in the table of prefixes to be locked 0 for all Telecom local and long distance calls A 1 Lift the receiver A 2 Press the key A 3 Dial the sequence A 4 After receiving the confirmation tone hang up B Fill in the table of ...

Страница 46: ...ble of prefixes to be locked 0 and 00 for all local and long distance calls A 1 Lift the receiver A 2 Press the key A 3 Dial the sequence A 4 After receiving the confirmation tone hang up A 5 Lift the receiver A 6 Press the key A 7 Dial the sequence A 8 After receiving the confirmation tone hang up Go to point B nn Prefix to be locked 01 0 02 00 1 2 3 4 0 1 nn R 0 Password ex 1234 From the table o...

Страница 47: ...B 3 Dial the sequence B 4 After receiving the confirmation tone hang up C Fill in the table of enabled carriers define the carriers for long distance calls C 1 Lift the receiver C 2 Press the key C 3 Dial the sequence C 4 After receiving the confirmation tone hang up C 5 Lift the receiver C 6 Press the key C 7 Dial the sequence C 8 After receiving the confirmation tone hang up Go to point D 8 CALL...

Страница 48: ...or all calls with numbers which begin with 00 international but the other numbers which begin with 0 are locked because they are in the table of prefixes to be locked Password ex 1234 1 2 3 4 0 1 nn prefix R 0 From the table of the prefixes to be unlocked for carrier 1 3 8 1 Password ex 1234 1 2 3 4 0 1 nn prefix R From the table of prefixes to be unlocked for carrier 2 3 8 2 0 0 D Fill in the tab...

Страница 49: ...ional calls and the second carrier 02 for satellite calls A Fill in the table of prefixes to be locked 0 for all local and long distance calls 0088 for all satellite calls A 1 Lift the receiver A 2 Press the key A 3 Dial the sequence A 4 After receiving the confirmation tone hang up A 5 Lift the receiver A 6 Press the key A 7 Dial the sequence A 8 After receiving the confirmation tone hang up Go t...

Страница 50: ...for Milan 02 for Rome 06 etc B 1 Lift the receiver B 2 Press the key B 3 Dial the sequence B 4 After receiving the confirmation tone hang up Go to point C 0 2 1 2 3 4 0 1 nn R Password e g 1234 From the table of prefixes to be unlocked prefix 3 7 1 nn Prefix to be unlocked max 4 numbers 01 02 for Milan 8 CALL LOCK MANAGEMENT ...

Страница 51: ...plir le tableau des gérants autorisés il faut définir quels sont les gérants pour les communications interurbaines internationales et via satellite C 1 Lift the receiver C 2 Press the key C 3 Dial the sequence C 4 After receiving the confirmation tone hang up C 5 Lift the receiver C 6 Press the key C 7 Dial the sequence C 8 After receiving the confirmation tone hang up Go to point D nn Gérant Indi...

Страница 52: ... calls remain locked because 0088 is in the table of prefixes to be locked D 5 Lift the receiver D 6 Press the key D 7 Dial the sequence D 8 After receiving the confirmation tone hang up Note In this way carrier 02 is enabled only for satellite calls Password ex 1234 1 2 3 4 0 1 nn prefix R 0 From the table of the prefixes to be unlocked for carrier 1 3 8 1 D Fill in the table of prefixes to be un...

Страница 53: ...door door entry or video door entry station depending on the type of door entry or video door entry system to be connected Maximum distance between exchange and telephone 200 metres Maximum distance between exchange and outdoor station 200 metres with speaker unit item 335902 9 2 INSTALLING PABX EXCHANGE After arranging the cables connect the devices as indicated in the diagrams Install the PABX i...

Страница 54: ...s colour white or grey For a correct combination consult the tables below RP 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 COLOUR COMPACT TELEPHONES VIDEO SECTION WHITE Art 335022 GREY Art 335102 RP 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 Art 335023 Art 335103 COLOUR STANDARD TELEPHONES VIDEO SECTION GREY WHITE 1 2 3 4 5 6 7 8 9 0 1 2 3 RP R M1 4 5 6 7 8 9 Art 335032 Art 335102 1 2 3 4 5 6 7 8 9 0 1 2 3 RP R ...

Страница 55: ...ed video section video door entry telephones connect the braided cable 1 which comes with the Pivot telephone following the correspondence of the conductors as indicated in the table below 9 5 INSTALLING THE TELEPHONE TABLE MOUNTED VIDEO SECTION To install the telephones table mounted video section video door entry telephones connect the conductors to the terminals of the 8 way socket as indicated...

Страница 56: ...oor entry conversation is taking place a call is made from one of the two temporarily excluded speaker units you will hear a telephone busy tone One of the three outdoor stations can be fitted with a nameplate for address or other information The speaker units of outdoor stations 1 and 2 must be configured At rest the open door lock command acts on the main outdoor station 9 INSTALLATION OPTIONALS...

Страница 57: ... 4 5 6 7 8 9 RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 401 403 402 1 2 3 4 5 6 7 8 9 Telephone 1 Telephone 2 Telephone 3 Maximum distance between furthest away outdoor station PABX PABX telephone 200 m 200 m type of cable telephone pair 0 28 mm2 telephone pair 0 28 mm2 ...

Страница 58: ...b 1 a b 2 a b 3 a b 4 a b 5 a b 6 a b 7 a b 8 C NO a b U1 3 4 M P T R PLT1 a b IN a b OUT 9 INSTALLATION Call 1 Call 2 OPTIONALS Telephone line Exchange Warning connect the exchange and telephone protection PLT1 earth terminal to the earth of the electric system Main Outdoor Station 0 Outdoor Station N 2 Outdoor Station N 1 Pushbutton to open door lock 18V 4A impulsive Dedicated speaker unit item ...

Страница 59: ...9 RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 401 403 405 407 402 404 406 408 Telephone 1 Telephone 2 Telephone 3 Telephone 5 Telephone 7 Telephone 4 Telephone 6 Telephone 8 Door entry call 1 Door entry call 2 Maximum distance between furthest away outdoor station PABX PABX telephone 200 m 200 m type of cable telep...

Страница 60: ...X 1m BUS 344032 N P 3 BUS a b 1 2 3 4 5 6 7 8 9 0 RP R M1 1 2 3 4 5 6 7 8 9 a b RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 9 INSTALLATION 402 401 APARTMENT 1 APARTMENT 2 APARTMENT 3 Audio system with one door entry call connected to the riser of the 2 wire system audio 2 wire audio system riser Warning Arrange the configurators on interface item 346...

Страница 61: ... 1 2 3 4 5 6 7 8 9 0 RP R M1 1 2 3 4 5 6 7 8 9 a b RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 N N 2 N P NN1 3 RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 Warning Arrange the configurators on interface item 346810 as indicated in the diagram 402 401 APARTMENT 1 APARTMENT 2 and 3 APARTMENT 4 1st door entry call 2nd door entry call Audio system with two door entry calls connected to the riser of...

Страница 62: ...8 a b U1 3 4 M P T R 335818 a b RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 OFF ON a b IN a b OUT PLT1 P Warning Arrange the configurators on interface item 346810 as indicated in the diagram APARTMENT 1 APARTMENT 2 APARTMENT 3 Audio system with one door entry call connected to the riser of the 2 wire system video 401 Floor distribution block riser video door entry telephone 2 wire video system ...

Страница 63: ... M P T R 335818 a b 1 2 3 4 5 6 7 8 9 N N 3 P NN1 4 P a b IN a b OUT PLT1 Warning Arrange the configurators on interface item 346810 as indicated in the diagram APARTMENT 2 APARTMENT 5 Audio system with two door entry calls connected to the riser of the 2 wire system video 401 APARTMENT 1 402 riser Door entry call 1 Door entry call 2 1st door entry call 2nd door entry call APARTMENT 3 and 4 Teleph...

Страница 64: ...or digital systems Analog or digital system to the floor distribution Telephone line Exchange Interface Warning Interface item 335910 must be set up as a function of the system to which it is connected Note as a base the interface is supplied to be connected to an analog system 1 2 3 4 ON Digital system 1 2 3 4 ON Analog system Warning connect the exchange and telephone protection PLT1 earth termi...

Страница 65: ... 1 2 3 4 5 6 7 8 9 403 401 a b RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 402 1 2 3 4 5 6 7 8 9 9 INSTALLATION Telephone 1 Telephone 2 Telephone 3 Warning interface item 335910 must be located as close as possible to the exchange max distance 1 m ...

Страница 66: ...erface 335910 call 1 Interface 335910 call 2 Warning connect the exchange and telephone protection PLT1 earth terminal to the earth of the electric system Warning interface item 335910 must be located as close as possible to the exchange max distance 1 m Warning Interface item 335910 must be set up as a function of the different types of system by means of dip switches as follows Door entry call 1...

Страница 67: ...7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 1 2 3 4 5 6 7 8 9 401 403 405 407 402 404 406 408 Telephone 1 Telephone 2 Telephone 3 Telephone 4 Telephone 5 Telephone 6 Telephone 7 Telephone 8 Door entry call 1 Door entry call 2 ...

Страница 68: ...xchange Interface Riser 4 wire n system Warning connect the exchange and telephone protection PLT1 earth terminal to the earth of the electric system Warning Interface item 335910 must be set up as a function of the system to which it is connected Note as a base the interface is supplied to be connected to an analog system 1 2 3 4 ON Digital system 1 2 3 4 ON Analog system Warning interface item 3...

Страница 69: ...Terraneo 69 9 INSTALLATION a b RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 402 a b 401 a b RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 403 1 2 3 4 5 6 7 8 9 Telephone 1 Telephone 2 Telephone 3 ...

Страница 70: ...1 1 2 Blue Red White Orange Orange White Brown 3 4 5 6 Brown Sound Bus Power White Green 7 8 Green Video One call audio and video system connected to the dedicated outdoor station with two telephones video section video door entry units switched on at the same time Telephone line Exchange Main Outdoor Station Dedicated outdoor station 1 opening door lock pushbutton 18V 4A impulsive Camera module i...

Страница 71: ...llow GND 2 green V 3 blue tel line 4 white ltel line 5 brown sound 6 red acc 7 black VID 8 grey VID Blue Red Orange White Orange Green White Green OUT 336010 _ 2 1 230V a c 50Hz OUT The system configures itself on typing the Macrocommand 8 2 0 1 from any extension For more information consult the Video distributor manual 1 2 3 4 R 8 2 0 1 Lift the receiver Type Type Dial the password base 1234 Aft...

Страница 72: ... 3 4 7 8 1 yellow GND 2 green V 3 blue tel line 4 white ltel line 5 brown sound 6 red acc 7 black VID 8 grey VID Blue Red Orange White Orange Green White Green 1 2 Blue Red White Orange Orange White Brown 3 4 5 6 Brown Sound Bus Power White Green 7 8 Green Video 9 INSTALLATION Audio and video system with two calls connected to the dedicated outdoor station Lift the receiver Type Type Dial the pass...

Страница 73: ...Orange White Orange Green White Green 1 2 3 4 7 8 1 yellow GND 2 green V 3 blue tel line 4 white tel line 5 brown sound 6 red acc 7 black VID 8 grey VID Blue Red Orange White Orange Green White Green 1 2 3 4 7 8 1 yellow GND 2 green V 3 blue tel line 4 white tel line 5 brown sound 6 red acc 7 black VID 8 grey VID Blue Red Orange White Orange Green White Green 1 2 3 4 7 8 1 yellow GND 2 green V 3 b...

Страница 74: ...loor distributor of the analog or digital system 335818 PRI a b 1 a b 2 a b 3 a b 4 a b 5 a b 6 a b 7 a b 8 C NO a b U1 3 4 M P T R 230V a c 50 60Hz 6 1 2 3 4 5 6 7 8 9 a b 403 8 PE a b IN a b OUT PLT1 Telephone line Exchange Telephone Analog Digital system to the floor distribution ...

Страница 75: ...7 8 1 yellow GND 2 green V 3 blue tel line 4 white ltel line 5 brown sound 6 red acc 7 black VID 8 grey VID Blue Red Orange White Orange Green White Green 1 2 3 4 7 8 1 yellow GND 2 green V 3 blue tel line 4 white ltel line 5 brown sound 6 red acc 7 black VID 8 grey VID Blue Red Orange White Orange Green White Green 1 2 3 4 R 8 2 0 3 Lift the receiver Type Type Dial the password base 1234 After th...

Страница 76: ... Analog or digital system to the floor distribution Warning connect the exchange and telephone protection PLT1 earth terminal to the earth of the electric system Warning Interface item 335910 must be set up as a function of the system to which it is connected Note as a base the interface is supplied to be connected to an analog system 1 2 3 4 ON Digital system 1 2 3 4 ON Analog system Warning inte...

Страница 77: ...e activated from telephones with video section a b a b RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 401 403 402 1 yellow 2 green 3 blue tel line 4 white tel line 5 brown 6 red 7 black 8 grey GND V BELL ACC VID VID 1 2 3 4 5 6 7 8 9 Main telephone Pivot Video Telephone 2 Telephone 3 ...

Страница 78: ...igital system to the floor distribution Call 1 Call 2 Interface 335910 call 1 Warning connect the exchange and telephone protection PLT1 earth terminal to the earth of the electric system Warning Interface item 335910 must be set up as a function of the different types of system by means of dip switches as follows Door entry call 1 analog system Door entry call 2 analog system Door entry call 1 di...

Страница 79: ...tel line 5 brown 6 red 7 black 8 grey GND V BELL ACC VID VID 9 INSTALLATION Note in mixed audio and video systems the self switching on of the outdoor station service can only be activated from telephones with video section Interface 335910 call 2 To telephones 404 406 408 To telephones 403 405 407 Door entry call 1 Telephone Pivot Video Door entry call 2 Telephone Pivot Video Warning interface it...

Страница 80: ...nalog or digital system to the floor distribution Video distributor item 336810 Video distributor item 336810 Warning connect the exchange and telephone protection PLT1 earth terminal to the earth of the electric system Warning Interface item 335910 must be set up as a function of the system to which it is connected Note as a base the interface is supplied to be connected to an analog system 1 2 3...

Страница 81: ... 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 401 a b 403 RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 402 1 yellow 2 green 3 blue tel line 4 white tel line 5 brown 6 red 7 black 8 grey GND V BELL ACC VID VID 1 yellow 2 green 3 blue tel line 4 white tel line 5 brown 6 red 7 black 8 grey GND V BELL ACC VID VID 1 2 3 4 5 6 7 8 9 Telephone Pivot Video Telephone 3 Telephone Pivot Video ...

Страница 82: ...seconds the red LED should shine steadily If the red LED flashes the exchange is not switched on correctly make sure that the connector of accessory item 335919 has not been put into the IOIOI port 4 Lift the receiver of telephone 401 and press R you should hear a continuous tone 5 Dial 402 this makes an internal call to extension 402 answer from telephone 2 and check the sound connection between ...

Страница 83: ... calls on Telephone 5 Receive incoming telephone calls on Telephone 6 Receive incoming telephone calls on Telephone 7 Receive incoming telephone calls on Telephone 8 Telephone 1 enabled for outgoing telephone calls Telephone 2 enabled for outgoing telephone calls Telephone 3 enabled for outgoing telephone calls Telephone 4 enabled for outgoing telephone calls Telephone 5 enabled for outgoing telep...

Страница 84: ...n Telephone 3 Receive door entry calls on Telephone 4 Receive door entry calls on Telephone 5 Receive door entry calls on Telephone 6 Receive door entry calls on Telephone 7 Receive door entry calls on Telephone 8 Telephone 1 enabled door entry functions Telephone 2 enabled door entry functions Telephone 3 enabled door entry functions Telephone 4 enabled door entry functions ...

Страница 85: ...expanded adding a series of devices which increase its performance Video distributor item 335918 Video expander item 335925 Relay expansion module item 335916 Door entry interface module for analog and digital systems item 335910 Door entry interface module for the 2 wire system item 346810 Dedicated speaker unit for PABX item 335902 ...

Страница 86: ... with the PABX telephone exchanges item 335818 or 335828 produced from batch 0127 6 and its star wiring can quickly and easily produce single or two family video door entry telephone systems with one or two divisions Using the distributor means that all the telephones with video section not only provide all the door entry and telephone services but also provide CCTV of communal and or private area...

Страница 87: ...2 3 4 5 6 7 8 9 RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 RP 1 3 2 4 6 5 7 9 8 0 R M1 1 2 3 4 5 6 7 8 9 OS 1 OS 2 IS IS IS OS 3 11 EXPANDABILITY 11 2 VIDEO EXPANDER ITEM 335925 The video expander with the video distributor item 335918 and the PABX telephone exchanges item 335818 and 335828 produced from batch 0127 6 can further expand the video doo...

Страница 88: ...916 must be supplied with a separate transformer see diagram on the instructions with item 335916 11 3 RELAY EXPANSION MODULE ITEM 335916 Each exchange can manage a maximum of 8 relays in addition to the internal relay for switching on the staircase light A maximum of 2 item 335916 can thus be connected Dimensions 3 DIN modules Contact output 6 A resistive 2 A inductive at cos j 0 5 voltage 230 V ...

Страница 89: ...d set up for analog riser If installed on a digital riser position dip switch 3 on ON Dimensions 3 DIN modules POTENTIOMETER ADJUSTMENT LOUDSPEAKER VOLUME POTENTIOMETER ADJUSTMENT MICROPHONE VOLUME CONNECT TO TERMINALS 3 AND 4 OF THE TELEPHONE EXCHANGE DIP SWITCH FOR ANALOG SYSTEM FOR DIGITAL SYSTEM 1 Open door lock off 2 seconds on 10 seconds 2 Interface off door entry call 1 on door entry call 2...

Страница 90: ...ed with the 2 wire interface if produced with production batch 0116 6 or later 11 5 DOOR ENTRY INTERFACE MODULE FOR THE 2 WIRE SYSTEM ITEM 346810 This interface module must be used to connect the exchange to the riser of the 2 wire system both audio and video The interface must be suitably configured Dimensions 3 DIN modules 2 wire system Exchange Art 335828 P indicates on which outdoor station ke...

Страница 91: ... the confirmation tone hang up 11 EXPANDABILITY Deactivating 2 wire interface from extension Pour la désactivation de l interface 2 fils il faut exécuter la procédure suivante Lift the receiver Press the R key you will hear the start dialling tone Type Dial the password e g base 1 2 3 4 After the start dialling tone type the Macrocommand 7 7 0 0 After receiving the confirmation tone hang up Activa...

Страница 92: ...he speaker unit of the main outdoor station must not be configured Operation The system automatically switches to the outdoor station from which the call was made If a call is made from one of the two temporarily excluded speaker units you will hear a telephone busy tone Idle the door lock command acts on the main outdoor station As a base the staircase light button of the speaker unit is associat...

Страница 93: ... 332520 Camera module item 332520 can be connected to the speaker unit to make video systems The camera can be rotated for optimum view Installing the speaker unit with nameplate module item 342200 A nameplate module for item 342200 can be connected to the speaker unit to show the street number or other information ...

Страница 94: ...programming from PC item 335919 can be used for easier exchange programming The TIPBX programming software can be downloaded free from the BTicino Internet site address www bticino it software section Exchanges item 335828 produced from batch 0127 6 can work together with video Distributor item 335918 and Video Expander item 335925 to program systems of this type the TIPBX software must be version...

Страница 95: ...ical and environmental characteristics Weight 900 gr Working temperatures 0 C 40 C Timing of internal tones start dialling tone continuous two tone call control tone free 1 s 4 s busy tone 500 ms 500 ms time out tone 100 ms 100 ms overcrowded tone 200 ms 200 ms on hold tone 200 ms 200 ms 200 ms 3400 ms alerting tone 100 ms 4900 ms confirmation tone 100 ms 100 ms 100 ms 100 ms 100 ms 1500 ms config...

Страница 96: ... requirements indicated below BTicino S p A Via Messina 38 21154 MILAN declares that the product with item No 335818 conforms to the essential requirements of directive 1999 5 EC in that it respects the following standards EN 60950 EN 50081 1 EN 50082 1 ETSI TBR21 ETSI ES 201 187 V 1 1 1 Year of Approval EC marking according to the directive indicated 2001 ...

Страница 97: ...Terraneo 97 NOTES ...

Страница 98: ...PABX 18D 98 NOTES ...

Страница 99: ......

Страница 100: ...BTicino s p a Via Messina 38 20154 MILAN Italy www bticino com ...

Отзывы: