![Brother RH-981A Скачать руководство пользователя страница 97](http://html.mh-extra.com/html/brother/rh-981a/rh-981a_service-manual_2819842097.webp)
5. POWER SUPPLY EQUIPMENT
RH-981A
89
P2 [SYNCHRO] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. XHR-5)
Pin no.
Signal name
Probable symptoms due to poor contact
1
+5V
2
Encoder timing signal
3
Needle down signal
4
Needle up signal
5
0V
• Machine motor does not run.
• Sewing machine motor is running unevenly.
• One of error codes E10, E40, E70, E71, E76, E77,
and E91 appears.
P3 [HEAD] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. XHR-9)
Pin no.
Signal name
Probable symptoms due to poor contact
1
Emergency stop switch normal close
signal
2
0V (for emergency stop switch)
3
Emergency stop switch normal open signal
4
-
5
-
6
-
• Error code E60 appears and machine stops.
• One of error codes E00, E12, E30, E42, and E72
appears.
7
+5V (for knife ON sensor)
8
Knife ON sensor signal
9
Knife ON sensor cathode
P4 [AIR] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. H12P-SHF-AA)
Pin no.
Signal name
Probable symptoms due to poor contact
1
Upper thread adjuster valve signal
2
Upper thread trimmer valve signal
3
Lower thread trimmer valve signal
4
Knife driving valve signal
5
Cloth opener valve signal
6
-
7
-
8
Work clamp valve
9
-
10
+24V (for work clamp, cloth opener, and
lower thread trimmer)
11
+24V (for upper thread adjuster, upper
thread trimmer, and knife driving)
12
-
• Upper thread adjuster does not work.
• Upper thread can not be trimmed.
• Lower thread can not be trimmed.
• Knife does not work.
• Cloth opener does not work.
• Work clamp does not work.
• One of error codes E12, E15, E42, E45, E72, and
E75 appears.
P5 [SOL] (not connected)
P6 [YPM] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. VHR-5N [blue])
Pin no.
Signal name
Probable symptoms due to poor contact
1
Y-axis PM driving current (YA)
2
Y-axis PM driving current (YB)
3
Y-axis PM driving current (YC)
4
Y-axis PM driving current (YD)
5
Y-axis PM driving current (YE)
• Back and forth motion of feed bracket is not correct.
• Y-axis home position can not be found.
• Error code E81 appears.
P7 [XPM] (JAPAN SOLDERLESS TERMINAL MFG. CO., LTD. VHR-5N)
Pin no.
Signal name
Probable symptoms due to poor contact
1
X-axis PM driving current (XA)
2
X-axis PM driving current (XB)
3
X-axis PM driving current (XC)
4
X-axis PM driving current (XD)
5
X-axis PM driving current (XE)
• Left and right motion of feed bracket is not correct.
• X-axis home position can not be found.
• Error code E80 appears.
Содержание RH-981A
Страница 8: ...RH 981A ...
Страница 23: ...2 DISASSEMBLY RH 981A 15 2 7 Needle bar thread take up and zigzag mechanisms 3710Q 3711Q 3709Q 3708Q ...
Страница 92: ...5 POWER SUPPLY EQUIPMENT RH 981A 84 Control circuit board Power supply circuit board 3530Q 3531Q ...
Страница 119: ...6 AIR PRESSURE MECHANISM RH 981A 111 5 Cloth opener cylinder 6 Lower thread trimming cylinder 3554Q 3555Q ...
Страница 136: ...7 SOFTWARE RH 981A 128 7 6 Control circuit block diagram 1 3842Q ...
Страница 137: ...7 SOFTWARE RH 981A 129 7 7 Control circuit block diagram 2 3843Q ...
Страница 138: ...SERVICE MANUAL Printed in Japan RH 981A I3080846H 2003 10 H 1 http www brother com ...