4. ADJUSTMENT
RH-981A
49
4-2. Adjusting the position of the work clamp plate
Before this adjustment, make sure that adjustment in “4-5. Adjusting the X-axis home position” has been completed.
Adjust so that the throat plate (1) and the needle plate R (2) do not make contact during sewing.
The standard clearance between the throat plate (1) and the needle plate R (2) is 1.3 mm (when the cutting space is
set to 0).
1. Use the parameter settings to set the cutting space to "0".
2. Select the test feed mode, and press the start switch.
3. Keep pressing the start switch, and make sure that the clearance between the throat plate (1) and the needle
plate R (2) is 1.3 mm.
4. If the clearance is not 1.3 mm, loosen the nut (3), and turn the bolt (4) to adjust the clearance.
Note:
Adjust the clearance between the throat plate (1) and the needle plate L in the same manner.
* If the maximum stitch width correction amount is set to 2.0 mm, adjust the distance between the throat plate and
the needle plate to more than 2.0 mm.
1.3 mm
3094Q
3095Q
Increase
Decrease
Содержание RH-981A
Страница 8: ...RH 981A ...
Страница 23: ...2 DISASSEMBLY RH 981A 15 2 7 Needle bar thread take up and zigzag mechanisms 3710Q 3711Q 3709Q 3708Q ...
Страница 92: ...5 POWER SUPPLY EQUIPMENT RH 981A 84 Control circuit board Power supply circuit board 3530Q 3531Q ...
Страница 119: ...6 AIR PRESSURE MECHANISM RH 981A 111 5 Cloth opener cylinder 6 Lower thread trimming cylinder 3554Q 3555Q ...
Страница 136: ...7 SOFTWARE RH 981A 128 7 6 Control circuit block diagram 1 3842Q ...
Страница 137: ...7 SOFTWARE RH 981A 129 7 7 Control circuit block diagram 2 3843Q ...
Страница 138: ...SERVICE MANUAL Printed in Japan RH 981A I3080846H 2003 10 H 1 http www brother com ...