GT-3 Series
7. Troubleshooting
159
7-4. Error Messages
Here is a complete list of error messages that GT-3 shows. Make contact to your dealer or Brother when mark **
is in Solution, with the information of Error Code No and the message on the Display.
Error
code
Message
Meaning
Solution
1000
(INK LOW Black)
Black ink level is too low.
Prepare a new Black ink cartridge.
1001
(INK LOW Magenta)
Magenta ink level is too low.
Prepare a new Magenta ink cartridge.
1002
(INK LOW Cyan)
Cyan ink level is too low.
Prepare a new Cyan ink cartridge.
1003
(INK LOW Yellow)
Yellow ink level is too low.
Prepare a new Yellow ink cartridge.
1004
(INK LOW White-1)
White-1 ink level is too low.
Prepare a new White ink cartridge.
1005
(INK LOW White-2)
White-2 ink level is too low.
1006
(INK LOW White-3)
White-3 ink level is too low.
1007
(I INK LOW White-4)
White-4 ink level is too low.
1030
K Head Temp Rising
Temperature of Black Print Head
is increasing.
Wait with the printer unused, to decrease the
temperature. Confirm if the Flat Cable of the Print
Head is connected properly. Make contact to your
dealer or Brother if the issue is not solved.
1031
M Head Temp Rising
Temperature of Magenta Print
Head is increasing.
1032
C Head Temp Rising
Temperature of Cyan Print Head is
increasing.
1033
Y Head Temp Rising
Temperature of Yellow Print Head
is increasing.
1034
W1 Head Temp Rising
Temperature of White-1 Print
Head is increasing.
1035
W2 Head Temp Rising
Temperature of White-2 Print
Head is increasing.
1036
W3 Head Temp Rising
Temperature of White-3 Print
Head is increasing.
1037
W4 Head Temp Rising
Temperature of White-4 Print
Head is increasing.
1051
CR Motor Life
The Carriage Motor is worn.
**
1060
Temp Low:
The ambient temperature is below
the range that maintains the print
quality.
“xxx” is the current temperature.
Raise the room temperature.
1061
Temp High:
The ambient temperature is above
the range that maintains the print
quality.
“xxx” is the current temperature.
Drop the room temperature.
1070
Battery Life
The battery ran out.
**
1080
RTC not Adjusted
The internal clock has not been
set.
**
1100
Pump Tube Life
Exchange Pump Tube.
**
1111
Clean Tube W1
W1 needs to do Tube Cleaning. Execute Tube Cleaning W1.
1112
Clean Tube W2
W2 needs to do Tube Cleaning.
Execute Tube Cleaning W2.
1113
Clean Tube W3
W3 needs to do Tube Cleaning.
Execute Tube Cleaning W3.
1114
Clean Tube W4
W4 needs to do Tube Cleaning.
Execute Tube Cleaning W4.