36
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
53-1002373-02
Router modules
1
SYSLOG: May 28 16:22:35:<13>May 28 16:22:35 System: Module was inserted to slot 7
Module 7 is -d class, it can't work when router mpls is enabled.
Reset slot 7
SYSLOG: May 28 16:22:48 :<13>May 28 16:22:48 Module 7 is reset by mgmt (reason:
boot to interactive mode)
Power supply requirements for NI-MLX-10Gx8-M and NI-MLX-10Gx8-D modules
Table 14
lists the power supply requirements for each type of router when installing Gen-2 8-port
10 Gbps interface modules (NI-MLX-10Gx8-M and NI-MLX-10Gx8-D).
24-port 1 Gbps Ethernet copper RJ45 interface module
The 24-port 1 Gbps Ethernet copper interface module is available in the following formats:
•
BR-MLX-1GCx24-X-ML
•
BR-MLX-1GCx24-X
This module has 32 Mb of flash memory and contains 24 RJ45 physical ports, through which you
can connect your router to other network routers. BR-MLX-1GCx24-X-ML support s up to 512K IPv4
routes in hardware and BR-MLX-1GCx24-X version supports up to 1M IPv4 routes in hardware.
BR-MLX-1GCx24-X-ML does not include a software license, but can be upgraded to an X version
through a software license. Please contact Brocade to purchase the license upgrade.
TABLE 14
Power supply requirements for Gen-2 8-port 10 Gbps interface modules
Router type
Number of Gen-2
8-port 10 Gbps
interface modules
installed
Power supply requirements
MLXe-4
three
one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
four
two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
MLX-4 and
Brocade NetIron
XMR 4000
four
one 1200W PSU
for 1+1 redundancy, install two 1200W PSU
MLXe-8
seven
two 1200W PSU
for 2+2 redundancy, install four 1200W PSU
eight
three 1200W PSU
for 3+1 redundancy, install four 1200W PSU
Brocade NetIron
XMR 8000
eight
two 1200W PSU
for 2+2 redundancy, install eight 1200W PSU
All 16-slot routers sixteen
four 1200W PSU
for 4+4 redundancy, install eight 1200W PSU
All 32-slot routers thirty-two
four 2400W PSU
for 4+4 redundancy, install eight 2400W PSU
Содержание MLXe-16
Страница 11: ...Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide xi 53 1002373 02 Dangers 426...
Страница 12: ...xii Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02...
Страница 18: ...xviii Brocade MLX Series and NetIron XMR Hardware Installation Guide 53 1002373 02 Document conventions...
Страница 252: ...234 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide53 1002373 02 Verifying proper operation 3...
Страница 330: ...312 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 RJ45 procedures 5...
Страница 396: ...378 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Replacing fan assemblies 8...
Страница 432: ...414 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Brazil B...
Страница 452: ...434 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Dangers C...