330
Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
53-1002373-02
Managing switch fabric modules
7
Forcing HSF modules to operate in normal mode
NOTE
This procedure requires that you restart your router.
If necessary, you can configure HSF modules to operate in normal mode using the system-init
fabric-data-mode force normal command.
Brocade(config)# system-init fabric-data-mode force-normal
Syntax: [no] system-init fabric-date-mode force-normal
If you remove the forced normal condition using the no version of this command, you must enter
the write-memory command and restart the router.
Blocking discovery of G1 switch fabric modules
NOTE
This procedure requires that you restart your router.
In a router with both standard (G1) switch fabric modules and G2 HSF modules, you can block the
discovery of the G1 switch fabric modules by entering the system-init block-g1-sfm command.
Syntax: system-init block-g1-sfm
After you enter this command, enter the write -memory command and restart the router.
Содержание MLXe-16
Страница 11: ...Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide xi 53 1002373 02 Dangers 426...
Страница 12: ...xii Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02...
Страница 18: ...xviii Brocade MLX Series and NetIron XMR Hardware Installation Guide 53 1002373 02 Document conventions...
Страница 252: ...234 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide53 1002373 02 Verifying proper operation 3...
Страница 330: ...312 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 RJ45 procedures 5...
Страница 396: ...378 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Replacing fan assemblies 8...
Страница 432: ...414 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Brazil B...
Страница 452: ...434 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Dangers C...