Power specifications
The following power supply frequency requirements apply to Brocade MLX 4-slot, 8-slot, and 16-slot
routers:
•
AC Input Rating: 100 to 240V, 50/60 Hz, 16.0 A maximum per power supply
•
AC Operating Voltage Range: 90 - 264V, 50/60 Hz
•
Inrush current: 40A peak maximum at 25 degrees C (77 degrees F)
•
DC Input Rating: -48V, 30.0 A maximum per power supply
•
DC Operating Range: -40 to -60V
•
Inrush current: 45A peak maximum at 25 degrees C (77 degrees F)
The following power supply frequency requirements apply to the Brocade MLX-32 routers:
•
AC Input Rating: 200 -240V, 50/60 Hz, 16.0 A maximum per power supply
•
AC Operating Voltage Range: 180 to 264V
•
Inrush current: 30A peak maximum at 25 degrees C (77 degrees F)
•
DC Input Rating: -48V, 60.0 A maximum per power supply
•
DC Operating Range: -40 to -60V
•
Inrush current: 45A peak maximum at 25 degrees C (77 degrees F)
Table 57
lists power consumption information for Brocade MLX routers with all base components
installed, and with only the specified interface modules installed.
TABLE 57
Brocade MLX router power consumption values
Model
@100 VAC
@200 VAC
@-48VDC
Amps
Watts
BTU/hr
Amps
Watts
BTU/hr
Amps Watts
BTU/hr
MLX routers with 8x10G interface modules only
MLX-4
14
1389
4740
7
1389
4740
29
1389
4740
MLX-8
28
2760
9419
14
2760
9419
57
2760
9419
MLX-16
56
5591
19081
28
5591
19081
116
5591
19081
MLX-32
N/A
N/A
N/A
57
11391
38876
237
11391
38876
MLX routers with48-T-A interface modules only
MLX-4
15
1445
4967
7
1455
4967
30
1435
4967
MLX-8
29
2893
9873
14
2893
9873
60
2893
9873
MLX-16
59
5857
19991
29
5857
19991
122
5857
19991
MLX-32
N/A
N/A
N/A
60
11924
40696
248
11924
40696
MLX routers with legacy MLX interface modules only
MLX-4
13
1313
4480
7
1313
4480
27
1313
4480
MLX-8
26
2607
8899
13
2607
8899
54
2607
8899
Содержание MLXe-16
Страница 11: ...Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide xi 53 1002373 02 Dangers 426...
Страница 12: ...xii Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02...
Страница 18: ...xviii Brocade MLX Series and NetIron XMR Hardware Installation Guide 53 1002373 02 Document conventions...
Страница 252: ...234 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide53 1002373 02 Verifying proper operation 3...
Страница 330: ...312 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 RJ45 procedures 5...
Страница 396: ...378 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Replacing fan assemblies 8...
Страница 432: ...414 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Brazil B...
Страница 452: ...434 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Dangers C...