Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide
327
53-1002373-02
Managing the device
7
Displaying the Syslog configuration and static and dynamic buffers
To display the Syslog parameters currently in effect on a device, enter the show logging command
from any level of the CLI.
Syntax: show logging
Table 47
describes the Syslog output buffer configuration information, in the rows above the log
entries.
SNM<
number
>
The temperature of the switch fabric module.
LP<
number
>
The temperature of the interface module.
Temperature Monitoring Poll
Period
The interval at which the system reads the temperature sensor on the
management, switch fabric, interface, and fan control modules.
MAC address
Backplane EEPROM MAC
Address
The MAC address of the device.
TABLE 47
Syslog buffer configuration
Field Description
Syslog logging
The state (enabled or disabled) of the Syslog buffer.
messages dropped
The number of Syslog messages dropped due to user-configured filters. By default, the
software logs messages for all Syslog levels. You can disable individual Syslog levels, in
which case the software filters out messages at those levels. Each time the software
filters out a Syslog message, this counter is incremented.
flushes
The number of times the Syslog buffer has been cleared by the clear logging
command. For information about clearing the Syslog buffer, refer to
“Static and
dynamic buffers”
on page 328.
overruns
The number of times the dynamic log buffer has filled up and been cleared to hold new
entries. For example, if the buffer is set for 100 entries, the 101st entry causes an
overrun. After that, the 201st entry causes a second overrun.
level
The message levels that are enabled. Each letter represents a message type and is
identified by the key (level code) below the value. If you disable logging of a message
level, the code for that level is not listed.
messages logged
The total number of messages that have been logged since the software was loaded.
level code
The message levels represented by the one-letter codes.
TABLE 46
show chassis command output (Continued)
Field
Description
Brocade> show logging
Syslog logging: enabled (0 messages dropped, 0 flushes, 0 overruns)
Buffer logging: level ACDMEINW, 7 messages logged
level code: A=alert C=critical D=debugging M=emergency E=error
I=informational N=notification W=warning
...
Содержание MLXe-16
Страница 11: ...Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide xi 53 1002373 02 Dangers 426...
Страница 12: ...xii Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02...
Страница 18: ...xviii Brocade MLX Series and NetIron XMR Hardware Installation Guide 53 1002373 02 Document conventions...
Страница 252: ...234 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide53 1002373 02 Verifying proper operation 3...
Страница 330: ...312 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 RJ45 procedures 5...
Страница 396: ...378 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Replacing fan assemblies 8...
Страница 432: ...414 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Brazil B...
Страница 452: ...434 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Dangers C...