Verifying proper operation
3
Syntax: show module
The Status column shows the module status. The management module status can be one of the
following:
•
ACTIVE – The module is currently the active management module.
•
STANDBY – The module is currently the standby management module.
•
COMING UP – The module is coming up as the standby module. This status occurs if the
standby management module becomes the active module during a switchover.
The switch fabric module status can be one of the following:
•
ACTIVE – The module is up and running.
•
BAD – The management module cannot initialize the switch fabric module.
An interface module status can be one of the following:
•
CARD_STATE_INIT – The system detects the module but the module is not up and running yet.
•
CARD_STATE_BOOT – The module is booting.
•
CARD_STATE_INTERACTIVE – The module is booting from interactive mode.
•
CARD_STATE_LP_SYNC – The software images are synchronized between the management
module and interface module.
•
CARD_STATE_SYNC – The system is currently synchronizing the software image between the
management module and interface module.
•
CARD_STATE_SOFTWARE_LOADED – The module has loaded the software image.
•
CARD_STATE_POWER_OFF – The module does not have power.
•
CARD_STATE_UP – The module is operating normally.
•
CARD_STATE_FAILED – The management module was unable to bring up an interface module.
If you see this status, make certain that the interface module is installed properly. For more
information, refer to
“Installing Brocade MLX-4 modules”
on page 158,
“Installing Brocade
MLX-8 modules”
on page 167,
“Installing Brocade MLX-16 router modules”
on page 178, or
“Installing Brocade MLX-32 router modules”
on page 209.
•
CARD_DOWN_REASON_
<explanation>
– The module is in a nonfunctional state. This status
appears with an explanation for why the module is down. For example,
"CARD_DOWN_REASON_BOOT_FAILED.” If the explanation does not help you resolve the
problem, contact technical support and provide the explanation included with this status.
Brocade# show module
Module Status Ports Starting MAC
M1 (upper): Brocade router Mgmt Module Active
M2 (lower):
F0: Brocade router Switch Fabric Module Active
S1:
S2:
S3:
S4: Brocade router 4-Port 10Gig Module CARD_STATE_UP 4 000c.db80.0000
S5: Brocade router 4-Port 10Gig Module CARD_STATE_UP 4 000c.db80.0000
S6: Brocade router 4-Port 10Gig Module CARD_STATE_UP 4 000c.db80.0000
S7:
S8:
Содержание MLXe-16
Страница 11: ...Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide xi 53 1002373 02 Dangers 426...
Страница 12: ...xii Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02...
Страница 18: ...xviii Brocade MLX Series and NetIron XMR Hardware Installation Guide 53 1002373 02 Document conventions...
Страница 252: ...234 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide53 1002373 02 Verifying proper operation 3...
Страница 330: ...312 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 RJ45 procedures 5...
Страница 396: ...378 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Replacing fan assemblies 8...
Страница 432: ...414 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Brazil B...
Страница 452: ...434 Brocade MLX Series and Brocade NetIron XMR Hardware Installation Guide 53 1002373 02 Dangers C...