Hardware features
1
If you attach both the copper and fiber connectors for a port to the network, the fiber connector
takes precedence over the copper connector. These ports support true media automatic detection,
meaning the device selects the fiber or copper connector based on link availability. If a fiber link
cannot be established, the device selects the copper media.
Typical uses of these ports include but are not limited to the following:
•
Connecting a PC through which you can access the system directly or through a Telnet
connection and configure, monitor, and manage the FSX system.
•
Connecting a Gigabit Ethernet switch, which will provide connectivity to your existing
management network. You can then access the FSX system and configure, monitor, and
manage the system from a management station.
NOTE
The existing management networks into which you can connect the Gigabit Ethernet ports must be
separate and isolated from the network over which user packets are switched and routed as shown
in
.
FIGURE 10
Separate management and switching or routing networks
LEDs on the FSX management module
The FSX management module provides status information using the LEDs listed in
. The
location of the LEDs is as follows:
•
The fiber connectors use the LEDs located beneath the mini-GBIC slots.
•
The copper connectors use square LEDs located in the upper right and left corners of the
upper Gigabit copper connectors. The LED on the left side is for the upper copper connector.
The LED on the right side is for the lower copper connector.
describes the LEDs on the FSX management module.
1
Management port
2
Interface port
TABLE 5
FSX management module LEDs
LED
Description and Position
State
Meaning
Pwr
Round LED located to the left
of the console port
On (Green)
The module is receiving power.
Off
The module is not receiving power.
t
FastIron Super X
d
SYS
EJECT
SYS
EJECT
SYS
EJECT
SYS
EJECT
2
1
FastIron SuperX
Management
Network
Switching and
Routing Network
Содержание FastIron SX 1600
Страница 8: ...viii Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 ...
Страница 96: ...68 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Verifying proper operation 2 ...
Страница 114: ...102 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Removing MAC address entries 4 ...
Страница 200: ...188 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Detailed procedure A ...
Страница 204: ...192 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Russia B ...