Internal airflow in the
FSX 1600
FSX 1600-ANR
The fan trays in the
FSX 1600
-ANR are located in the top rear of the chassis.
The fans cool the CPU, main memory, and voltage regulators. The fans move the air from the front
of the device to the rear of the device, as shown in
. The hot air exits the chassis through
the bottom of the ANR kit.
TABLE 27
FSX 1600 chassis fan operating noise
Fan Speed Setting
Airflow (CFM)
Exhaust
Acoustic Level (dB)
Front
Left
Right
Rear
1
282
59
58
58
65
2
388
65
66
66
72
3
391
65
66
66
72
4
395
65
66
66
72
5
454
68
69
71
78
Cool air enters from
the front, left, and right sides
Hot air exits from the rear