Brocade FastIron X Series Chassis Hardware Installation Guide
99
53-1001723-02
Syslog messages for PCI (hardware) errors
4
The message types that appear in the static buffer do not appear in the dynamic buffer. The
dynamic buffer contains up to the maximum number of messages configured for the buffer (50 by
default), then begins removing the oldest messages (at the bottom of the log) to make room for
new ones.
The static and dynamic buffers are both displayed when you display the log.
When you clear log entries, you can selectively clear the static or dynamic buffer, or you can clear
both. For example, to clear only the dynamic buffer, enter the following command at the Privileged
EXEC level.
FastIron# clear logging dynamic-buffer
Syntax: clear logging [dynamic-buffer | static-buffer]
You can specify the dynamic-buffer keyword to clear the dynamic buffer or the static-buffer keyword
to clear the static buffer. If you do not specify a buffer, both buffers are cleared.
Syntax: show log
Syslog messages for PCI (hardware) errors
FastIron
Chassis devices support the display of PCI (hardware) read and write errors encountered
on a slot or module during bootup and during normal system operations. There are four types of
PCI errors, which may cause the system to disable or power down the module or modules on which
they occur:
•
Configuration read error
•
Configuration write error
•
Memory read error
•
Memory write error
For more information, refer to the “
Using Syslog
” chapter in the
FastIron Configuration Guide
.
Managing the switch fabric modules (
FSX 800
and
FSX 1600
only)
If desired, you can disable power to a switch fabric module and then reenable it. To disable the
power, enter the following command at the Privileged EXEC level of the CLI.
FastIron(config)# show logging
...
Static Log Buffer:
Aug 27 12:42:42:A:Power Supply 6, 1st right, failed
Dynamic Log Buffer (50 lines):
Aug 27 12:19:04:I:Interface ethernet3/4, state up
Aug 27 12:19:04:I:Interface ethernet6/3, state up
Aug 27 12:19:04:I:Interface ethernet3/2, state up
Aug 27 12:19:04:I:Interface ethernet6/1, state up
Aug 27 12:19:00:N:Module up in slot 6
Aug 27 12:19:00:N:Module up in slot 3
Aug 27 12:18:43:I:Warm start
Содержание FastIron SX 1600
Страница 8: ...viii Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 ...
Страница 96: ...68 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Verifying proper operation 2 ...
Страница 114: ...102 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Removing MAC address entries 4 ...
Страница 200: ...188 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Detailed procedure A ...
Страница 204: ...192 Brocade FastIron X Series Chassis Hardware Installation Guide 53 1001723 02 Russia B ...