31
Installation
Phenolic Privacy Restroom Partitions, Floor-to-Ceiling — Series 700, — 69", 72" & 69"/72" Tall
Bradley •
HDWC-INSTR-045 Rev. A: ECO 20-14-002S
6/25/2021
Flat Strike at Wall – Outswing
Flat Strike at Pilaster – Outswing
Using the flat strike as a template, mark the hole
locations on the wall . Remove the flat strike and drill a
Ø1/4" hole (min . 2" (51) deep) at each hole location .
M
Using the flat strike as a template, mark the hole
locations on the pilaster . Remove the flat strike and drill a
Ø11/64" hole (min . 1/2" (13) deep) at each hole location .
Q
Insert the plastic anchors in all of the holes and secure
the flat strike to the wall using the #10 x 2" screws
provided .
N
Secure the flat strike to pilaster wall using the
#10 x 1" screws provided .
R
Refer to Step G for installing the keeper and Step K for
installing the dampening strip .
O
Refer to Step G for installing the keeper and Step K for
installing the dampening strip .
S
With the door in the closed position, place the
non-notched edge of the flat strike against the wall . The
notched edge of the door should fit into the notch on the
flat strike . The top edge of the flat strike and door should
align along with the front faces .
L
With the door in the closed position, place the
non-notched edge of the flat strike against the pilaster .
The notched edge of the door should fit into the notch
on the flat strike . The top edge of the flat strike and door
should align along with the front faces .
P
Wall
9a Door Hardware for Outswing Doors (continued)
Pilaster
Flat Strike
Outswing Door
Flat Strike
Outswing Door