27
Installation
Phenolic Privacy Restroom Partitions, Floor-to-Ceiling — Series 700, — 69", 72" & 69"/72" Tall
Bradley •
HDWC-INSTR-045 Rev. A: ECO 20-14-002S
6/25/2021
9
Door Hardware for Inswing Doors (continued)
3"
(76)
3" (76)
Clean the strike pilaster notched surface using isopropyl
alcohol (by others) . Remove a dampening strip from the
liner and place the top edge 3" (76) down from the top
notch; apply pressure to adhere to the pilaster . Remove
the second dampening strip from the liner and place the
bottom edge 3" (76) up from the bottom notch, and apply
pressure to adhere to the pilaster .
For 34"–36" doors, mark the location for the top hole
on the inside face of the door 36-3/4" (933) up from the
bottom of 72" tall doors or 33-3/4" (781) up from the
bottom of 69" tall doors (42-3/4" (1086) above finished
floor) and 6-1/2" (165) from the door edge . Drill (2) Ø1/4"
holes (spaced 3-1/2" (89) apart) through the door and
secure the door pulls to the door as shown with the
#10-24 x 2" flat machine screws provided .
H
J
Place the coat hook 3" (76) down from the top and 3" (76)
from the latch side of the door (hook goes on the inside
face of the door) . Using the hook as a template, drill
(2) Ø11/64" pilot holes, 5/8" (16) deep . Secure with the
#10 x 5/8" screws provided .
I
6-1/2"
(165)
3"
(76)
36-3/4" (933)
(Bottom of 72" Tall Door)
33-3/4" (857)
(Bottom of 69" Tall Door)
42-3/4" (1086)
A .F .F