Phenolic Privacy Restroom Partitions, Floor-to-Ceiling — Series 700, — 69", 72" & 69"/72" Tall
Installation
6/25/2021
Bradley •
HDWC-INSTR-045 Rev. A: ECO 20-14-002S
2
Stirrup Brackets to Wall (Standard)
Established Level Line
Pilaster/Panel Plumb Line
Floor
CL
Place the center of each stirrup bracket
at the established level line . Center the
bracket opening on the pilaster/panel
plumb line .
A
Insert the plastic anchors in all holes and
secure the brackets to the wall with the
#14 x 2" screws provided .
C
On end panel and pilaster applications, position the bracket
with the ear facing toward the inside of the stall.
Using the bracket as a template, mark
the hole locations on the wall . Remove
the bracket and drill a Ø5/16" hole (min .
2" (51) deep) at each hole location .
B
One-Eared
Bracket
Two-Eared
Bracket
Pilaster bracket is shown here. 3/4" (19) opening brackets are
for pilasters and 1/2" (13) opening brackets are for panels.
2a Continuous Stainless Steel Brackets to Wall (Optional)
Established Level Line
Pilaster
Plumb Line
Floor
CL
Place the bottom of each continuous
bracket at the established level line .
Center the bracket opening on the
pilaster/panel plumb line .
A
Insert the plastic anchors in all holes and
secure the brackets to the wall with the
#14 x 2" screws provided .
C
On pilaster applications, position the bracket with the ear
facing toward the inside of the stall.
Using the bracket as a template, mark
the hole locations on the wall . Remove
the bracket and drill a Ø5/16" hole (min .
2" (51) deep) at each hole location .
B
Brackets are used as templates, but since the hole patterns
may be different, the brackets may not be interchangeable.
'Ear'
Bracket
U-Bracket
Pilaster bracket shown here; 'Ear' brackets (3/4" (19) opening) for
pilasters and U-brackets (1/2" (13) opening) are for panels.