background image

6

Bradmar

 Restroom Partitions, Floor-Mounted with Overhead Brace — Series 400

 

Installation

10/1/2014 

Bradley

 • 

HDWP-INSTR-013 Rev. K; ECN 12-14-012

4a Stirrup Brackets to Pilaster (Optional)

Refer to the submittal drawing to locate the split 

dimension and layout location of each marked pilaster.

Locate Brackets:

 Measure down from the top of the pilaster 

and place a mark on the pilaster split centerline at dimension 

"A", "B" and "C" for the respective bracket (see table at left).

 Pilaster shown is for reference only.

Actual pilaster varies depending on application.

A

Place the center of each stirrup bracket at each 

established level line. Center the bracket opening 

on the panel plumb line. Using the bracket as 

a template, mark the hole locations on the 

pilaster. Remove the bracket and drill a Ø 

⁷⁄₃₂

" x 

¾"(19mm) deep pilot hole at each location.

B

Split

Split

"A"

"B"

"C"

"U" 

Bracket

"H" 

Bracket

Dim . "A"

19" 

(483mm)

13½" 

(343mm)

Dim . "B"

40½" 

(1029mm)

67½" 

(1715mm)

Dim. "C"

62" 

(1575mm)

Secure the stirrup brackets to 

the pilasters using the #14 x ¾" 

screws provided . 

Refer to step 4 for location and 

attachment of "H" bracket.

C

5

Pilaster Shoes 

This view is an example only. Refer to your submittal drawings for actual sizes. Layout the 

pilaster and door widths on the pilaster centerline, leaving the appropriate gap between 

the wall and pilaster . Place the corresponding shoe on the pilaster centerline, center the 

shoe between the pilaster marks. Using the shoes as a template, mark the hole locations.

A

Insert plastic anchors 

into the holes and fasten 

the shoe to the anchors 

using hardware provided .

C

Drill Ø 

⁵⁄₁₆

" holes (min 2" 

[51mm] deep) in the floor 

and make sure the holes 

are free of dirt and debris.

B

Install the shoes starting with the one closest to the wall

36" (914mm)

 

Door Opening

Pilaster Centerline

24" (610mm)

4" 

(102mm)

7" 

(178mm)

1" (25mm) Gap

26" (660mm)

 

Door Opening

⁹⁄₃₂

" x 

⁵⁄₈

" Flat Washer

#14 x 2" Screw

Stainless Steel Shoe

Plastic 

Anchor

Содержание Bradmar 400 Series

Страница 1: ...enance department Compliance and conformity to local codes and ordinances is the responsibility of the installer Separate parts from packaging and make sure all parts are accounted for before discardi...

Страница 2: ...ar saw Two spring clamps and drill bits Power drill or screw gun with drill bit extension Tape measure and 4 level ceramic tile and masonry drill bit Hammer drill Spacer 14 356mm high and strong enoug...

Страница 3: ...present the hole center line of the stirrup brackets Use a level to transfer that mark to all other plumb lines C Panel plumb line 63 1600mm 41 1054mm A B B1 A1 C C C C C C C C C 20 508mm C L C L C L...

Страница 4: ...Remove the bracket and drill a hole min 2 51mm deep at each hole location B One Eared Bracket Two Eared Bracket 2 Continuous Brackets to Wall Standard established level line pilaster panel plumb line...

Страница 5: ...Measure down from the top of the pilaster and place a mark on the pilaster split centerline at dimensions at 13 343mm and 67 1715mm Pilaster shown is for reference only Actual pilaster varies dependi...

Страница 6: ...Split A B C U Bracket H Bracket Dim A 19 483mm 13 343mm Dim B 40 1029mm 67 1715mm Dim C 62 1575mm Secure the stirrup brackets to the pilasters using the 14 x screws provided Refer to step 4 for locat...

Страница 7: ...13mm between the panel and pilaster Using the bracket as a template drill holes through the pilaster at each pilaster bracket hole Secure the pilaster to the bracket with 10 24 x barrel nuts and 10 24...

Страница 8: ...m between the panel and pilaster Using the brackets as a template drill holes through the pilaster at each pilaster bracket hole Secure the pilaster to the bracket with 10 24 x barrel nuts and 10 24 x...

Страница 9: ...spacing between the pilasters for the doors is the correct dimension On the back of each pilaster starting with the first pilaster drill a hole through one face of the headrail only Using this hole as...

Страница 10: ...rt the spring and the top pin into the pilaster top Move the top of the door into position while pushing the top pin into the pilaster Release the top pin and force the pin to bottom out in the door C...

Страница 11: ...3 Top Pin Lip Lip 3 76mm 3 Top Pintle 3 Bottom Pintle Assembly Notch Feature for adjacent door strike 19mm 1 44mm 13mm Drill first hole as shown Attach and align heat sink with single screw 6 x flat h...

Страница 12: ...a 8 x 1 flat head Phillips drive screw To adjust spring tension use a torx screwdriver and turn the torx head clockwise approximately one complete revolution Insert a 1 38mm long nail into the hole th...

Страница 13: ...d to the shoe and that the headrail is installed Determine the door swing by facing the compartment from the outside Refer to your submittal drawings to determine each specific door swing for your app...

Страница 14: ...or Use tape to hold the hinge sets together H Place the upper blank of the top hinge set on the door 2 51mm from the top Using the hinge as a template drill a x 1 25mm deep pilot hole into the edge of...

Страница 15: ...the door so that the slide bar is centered in the slot on the strike keeper The leading edge of the latch should be positioned approximately 10mm from the door edge Install the coat hook in the upper...

Страница 16: ...so that the slide bar is centered on the strike keeper The leading edge of the latch should be positioned approximately 1 25mm from the door edge Install the coat hook according to local codes For su...

Страница 17: ...as a template drill a pilot hole into the door 19mm deep Secure the latch to the door using hardware provided B With the door in the closed position mount the latch on the inside of the door so that...

Страница 18: ...A B G F H With the door in the closed position mount the latch on the inside of the door so that the center of the slide bar is 27 699mm from the top of the door The leading edge of the latch should b...

Страница 19: ...16 and larger B Using the bracket as a guide drill a x deep pilot hole at each screw hole location The stiffener bracket is installed on the largest side of a pilaster split B Using the bracket as a g...

Страница 20: ...hole locations on the wall Remove the bracket and drill a x min 2 51mm deep hole at each hole location C Place the bottom of the continuous bracket at the established level line Center the bracket ope...

Страница 21: ...e hole locations on the wall Remove the bracket and drill a x min 2 51mm deep hole at each hole location B Place the bottom of each urinal screen 18 457mm up from floor Establish a 1 25mm gap between...

Отзывы: