Installation
Bradmar
™
Restroom Partitions, Floor-Mounted with Overhead Brace — Series 400
Bradley
•
HDWP-INSTR-013 Rev. K; ECN 12-14-012
10/1/2014
3
Leveling bolts to Pilaster
Notch indicates
bottom of integral
hinge pilaster
Notch indicates
bottom of integral
hinge pilaster
Use leveling screw to adjust
height of pilaster
Use leveling screws to
adjust height of pilaster
Drill a Ø
¹³⁄₆₄
" pilot hole,
1½" (38mm) deep. Hole
should be approximately
centered for pilasters 3"–16"
(76mm–406mm) wide.
A
Drill a Ø
¹³⁄₆₄
" pilot hole, 1½" (38mm)
deep. Hole should be 2"(51mm)
off each end for the pilasters
18"–24"(457mm–610mm) wide.
A
4
Continuous Brackets to Pilaster (Standard)
Refer to the submittal drawing to locate the split
dimension and layout location of each marked pilaster.
Locate Brackets:
Measure down from the top of the
pilaster and place a mark on the pilaster split centerline
at dimensions at 13½"(343mm) and 67½"(1715mm).
Pilaster shown is for reference only. Actual pilaster
varies depending on application.
A
Secure the brackets.
For "H" Bracket:
Use the bracket as a
template, drill a Ø ¼" holes through the
pilaster/panel and secure the bracket to
the pilaster and panel with #10-24 x ¾"
barrel nuts and #10-24 x ¾" shoulder
screws provided .
For continuous bracket:
Secure the bracket
to the pilasters using the #14 x ¾" screws
provided .
C
Split
Split
13½"
(343mm)
67½"
(1715mm)
Place the continuous bracket between each established
level line. Center the bracket opening on the pilaster
split centerline. Using the bracket as a template, mark
the hole locations on the pilaster. Remove the bracket
and drill a Ø
⁷⁄₃₂
x ¾" (19mm) deep pilot hole at each
location .
B
Brackets are used as templates but, since the hole patterns may
be different, the brackets may not be interchanged.
C