UNPACKING/INSPECTION
1. Inspect carefully for any signs of damage.
2. All equipment is carefully manufactured, inspected and packed.
3. Any claims for damage or shortage in shipment must be filed immediately with the shipper and noted on the Bill of
Lading.
NOTICE
The vent terminal that is supplied with this water heater are stored at the top in the Combustion Assembly
Compartment. The condensate elbow and rubber couplers are secured to the bottom of the crating.
LOCATE WATER HEATER
1. Locate water heater in front of final position before removing crate.
2. LOCATE so that venting connections will be short and direct.
3. THIS WATER HEATER IS SUITABLE FOR INSTALLATION ON COMBUSTIBLE FLOOR. Do not install this
water heater directly on carpeting. If the water heater is to be installed on carpeting, it must be installed on top of
a metal or wood panel extending beyond the full width and depth of the appliance by at least three 3 inches
(7.6
cm)
in any direction or, if the appliance is to be installed in an alcove or closet, the entire floor must be covered by
the panel.
4. FOR BASEMENT INSTALLATION, provide a solid level elevated base such as concrete or other suitable pad to
raise the water heater at least 3” to provide a slope of 1/8” to 1/4” per foot for the condensate line to a suitable
drain.
5. Minimum clearance to combustible material is 0” for the Top, Sides, and Rear of this water heater. However, it is
recommended that
at least
18” from the Top, 24” from the Front, 4” for the Left Side and Rear, and 12”
from the Right Side Exhaust Elbow of the water heater be provided for servicing.
Clearance for servicing
may be reduced down to minimum clearance to combustible material, but service time and effort may be greatly
increased.
Figure 3a. Minimum Clearance to Combustible Material.