WARNING
Water heaters are heat-producing appliances. To avoid damage or injury there must be no materials stored against
the water heater or direct vent system, and proper care must be taken to avoid unnecessary contact (especially by
children) with the water heater and direct vent system. UNDER NO CIRCUMSTANCES SHOULD FLAMMABLE
MATERIALS, SUCH AS GASOLINE OR PAINT THINNER BE USED OR STORED IN THE VICINITY OF THIS
WATER HEATER OR IN ANY LOCATION FROM WHICH FUMES COULD REACH THE WATER HEATER.
Installation or service of this water heater requires ability equivalent to that of a licensed tradesman in the field
involved. Plumbing, air supply, venting, gas supply and electrical work are required.
Light the unit in accordance with the operating instructions label attached to the water heater.
Under no circumstances should the input rate exceed the input rate shown on the water heater rating plate. Over
firing could result in damage or sooting of the water heater.
If the unit is exposed to the following, do not operate water heater until all corrective steps have been made by a
factory authorized independent service contractor or qualified service professional.
1. Flooding to or above the level of the burner or controls
2. External firing
3. Damage
4. Firing without water
5. Sooting
NEVER OPERATE THE WATER HEATER WITHOUT FIRST BEING CERTAIN IT IS FILLED WITH WATER AND
A TEMPERATURE AND PRESSURE RELIEF VALVE IS INSTALLED IN THE RELIEF VALVE OPENING OF
THE WATER HEATER.
GENERAL INSTRUCTIONS
TO FILL THE WATER HEATER
1. Close the water heater drain valve by turning the knob or valve stem clockwise. If alternative water connections are
provided but not used, make certain they are plugged (i.e. rear connections).
2. Open the cold water supply shut-off valve.
3. Open several hot water faucets to allow air to escape from the system.
4. When a steady stream of water flows from the faucets, the water heater is filled. Close the faucets and check for
water leaks at the water heater drain valve, combination temperature and pressure relief valve and the hot and cold
water connections.
SEQUENCE OF OPERATION
1. Thermostat starts with heating cycle
2. Blower ON
3. Blower pre-purge at reduced speed
4. Spark rod sparks to the burner and gas valve opens – burner ignition
5. Flame signal confirmed with Main burner ON
6. Blower remains at reduced speed for a short period to stabilize flame
7. Blower increases to full speed for full input
8. Thermostat satisfied
9. Gas valve closes – Main burner OFF
10. Blower post purges, then OFF