WARNING
This water heater needs fresh air for safe operation and must be installed so there are provisions for adequate
combustion and ventilation air. Insufficient air supply will cause a recirculation of combustion products resulting in
contamination that may be hazardous to life. This will result in carboning or sooting of the combustion chamber, burners,
and flue tubes and creates a risk of asphyxiation.
This water heater requires its own separate venting system. DO NOT connect the exhaust vent into an existing vent
pipe or chimney.
Flammable items, pressurized containers or any other potential fire hazardous articles must never be placed on or
adjacent to the water heater. Open containers of flammable material should not be stored or used in the same room with
this water heater.
Insulation blankets are not required for this water heater. This water heater meets or exceeds the ASHRAE/IES 90.1b
(latest edition) standards with respect to insulation and standby loss requirements.
Hydrogen gas can be produced in an operating water heater that has not had water drawn from the tank for a long
period of time (generally two weeks or more). Hydrogen gas is extremely flammable. To prevent the possibility of injury
under these conditions, we recommend the hot water faucet to be open for several minutes at the kitchen sink before
you use any electrical appliance which is connected to the hot water system. If hydrogen is present, there will be
unusual sounds such as air escaping through the pipes as hot water begins to flow. Do not smoke or have open flame
near the faucet at the time it is open.
WARNING
Prior to connecting the gas supply line to a gas fired water heater, ensure that the gas supply line does not have
moisture/water or dirt/scale inside the gas line. Commonly this check is done at the lowest point in the gas distribution
system prior to gas burning appliances.
Do not use this appliance if any external part to the tank has been submerged in water. You should contact a qualified
service technician to inspect the appliance and to replace any part of the control system including the combination gas
control which has been submerged in water. See the Gas Connections section of this manual before servicing or
replacing a water heater that has had any external part to the tank submerged in water.
To comply with NSF requirements this water heater must be sealed to the floor with sealant, in a smooth and easily
cleanable way.
Liquefied petroleum gases/propane gas is heavier than air and will remain at floor level if there is a leak. Basements,
crawl spaces, closets and areas below ground level will serve as pockets for accumulation of leaking gas. Before
lighting, smell all around the appliance area for gas. Be sure to smell next to the floor.
IF YOU SMELL GAS:
DO NOT try to light any appliance.
DO NOT touch any electric switch; do not use any telephone in your building.
Immediately call your gas supplier from a telephone in another building. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
DO NOT OPERATE THE APPLIANCE UNTIL THE LEAKAGE IS CORRECTED!