An energy cut out (ECO) is incorporated in the sensor and control board which will shut off all gas supply to the burner if
the water heater temperature exceeds 200°F (
93°C
). Should the ECO function (open), the water temperature should be
reduced to approximately 120°F (
49°C
) and call a qualified service agent to place the water heater in operation. The
water heater must have the problem corrected by a qualified service person before putting the water heater back in
operation. It is recommended that all service work be performed by a qualified service agency.
If the water heater is to remain idle for 30 days or more or is subjected to freezing temperatures while shut off, the water
heater and piping should be fully drained (See “To Drain the Water Heater”) and the drain valve should be left fully open.
WARNING
Hydrogen gas can be produced in an operating water heater that has not had water drawn from the tank for a long
period of time (generally two weeks or more). Hydrogen gas is extremely flammable. To prevent the possibility of
injury under these conditions, we recommend the hot water faucet to be open for several minutes at the kitchen sink
before you use any electrical appliance which is connected to the hot water system. If hydrogen is present, there will
be an unusual sound such as air escaping through the pipes as hot water begins to flow. Do not smoke or have open
flame near the faucet at the time it is open.
WARNING
Do not run out of propane gas. Damage to the water heater may occur.