Figure 13. Typical Vertical Power Direct Vent System Installation.
(Note: Intake and exhaust terminals may be on different outside walls
.)
Through the Wall Venting With Low Ground Clearance
When venting cannot exit through the wall at a height greater than or equal to 12”
(30.5 cm)
(and above expected snow
level) from the ground, then the installation must be modified as shown below (see Figure 14). Refer to Tables 3 or 4 for
maximum venting lengths using 4 inches
(10.2 cm),
or 6 inch
(15.2 cm)
diameter
plastic pipe. When using low ground
clearance venting there still needs to be 36” of vent separation between intake and exhaust vent terminations.