- 39 -
Display notifications Meaning
19320012
WLAN JOIN
STOP
Tool cannot connect to the network.
TEMP MOT
STOP
Maximum temperature of the motor exceeded. Allow the tool
to cool down and check break times. If the error persists,
contact the manufacturer.
FAIL VCC MAX
STOP
Maximum logic voltage exceeded.
Tools must be repaired!
19320012
WLAN SCAN
STOP
The tool could not find the set network.
19320012
WLAN IP
STOP
Tool is in the wrong IP group.
FORCE MAX
STOP
Maximum permissible force exceeded, contact the manufacturer.
CUR MAX
STOP
Maximum permissible current exceeded, contact the
manufacturer.
TEMP FET
STOP
If the maximum temperature of the control unit is exceeded, contact
the manufacturer.
TARA ERROR
Sensor value error.
Contact manufacturer, tool must be checked.
NA MOTOR
Motor does not start correctly. Motor faulty or incorrect programming.
Check the last step of your program in the pulling direction. During this
step, Force
actual
must be activated. Nominal value of the tool must be
entered.
Содержание RTB-20
Страница 63: ... 63 evaluation Here you can define the travel and force range to be measured for each step ...
Страница 71: ... 71 355 44 23 24 53 31 72 303 75 Specifications in mm Not shown to scale ...
Страница 74: ...Notes ...
Страница 75: ...Notes ...
Страница 76: ...03 2021 www bossard com Technical data without guarantee Design suggestions are non binding Subject to changes ...