- 36 -
Display notifications Meaning
19320012
SCAN BARCODE
partnumber
1
Request for scan:
Component 1, 2 or 3 depending on the number in the building block of
the display must be scanned before the tool will be enabled.
19320012
pressure
Pressure trigger not actuated! To rivet, press the nose piece against the
part to be riveted.
19320012
Container
Rivet mandrel collector not screwed on or not screwed on correctly.
19320012
Fail pressure
Pressure trigger still pressed after riveting process when trying to rivet
again. First the pressure trigger must be released and actuated again.
For locking ring bolts and Huck adapter versions, switch off the pres
-
sure trigger in the SmartTool-Manager.
18360035
SERVICE
Cleaning interval of the jaws reached. Please clean the jaws and reset
the rivet counter in the software.
19320012
SCAN BARCODE
Product ID must be scanned before the tool is released. Symbol can be
represented as an aeroplane or a car.
19320012
SCAN IO
234
The scan of the barcode with the number "234" was successful.
P01
000/003
ENABLE 1
234
Tool was released for three riveting operations. No barcode was
scanned for the release, therefore the serial number is shown in the
release field.
SmartTool-Manager display setting:
Display - OLED display - Standard
19320012
DISABLE
HALT
The tool is not released.
For NOK results, the visualisation area is framed in red and the green result display is also
red.
Содержание RTB-20
Страница 63: ... 63 evaluation Here you can define the travel and force range to be measured for each step ...
Страница 71: ... 71 355 44 23 24 53 31 72 303 75 Specifications in mm Not shown to scale ...
Страница 74: ...Notes ...
Страница 75: ...Notes ...
Страница 76: ...03 2021 www bossard com Technical data without guarantee Design suggestions are non binding Subject to changes ...