6. The 5-pin spreader harness is
disconnected or has a faulty connection.
6. Clean the 5-pin connector at the
bumper. Check the continuity on the blue
and green wires.
6-7. The LED is flashing green.
7. The 4-pin controller connector has a
faulty connection.
7. Clean the 4-pin connector at the
controller. Check the continuity on the blue
and green wires.
8. The LED is slowly flashing red.
8. The button on the module is stuck.
8. Free the button or replace the module.
Button Stuck Error
There is a dead-face icon in the center of the controller screen.
Module Status
Possible Cause
Corrective Action
1. The LED is solid green.
1. The button on the controller is stuck.
1. Replace the controller.
2. The dump switch is stuck.
2. Replace the dump switch.
2-3. The LED is quickly flashing red.
3. The work-light switch is stuck.
3. Replace the work-light switch.
Top Screen Error
There is an open box icon in the center of the controller screen.
Module Status
Possible Cause
Corrective Action
1. The top screen is open.
1. Close the top screen.
1-2. The LED is solid green.
2. The top screen switch is not functioning.
2. Replace the top screen switch or latch.
Worklight Error
The center of the controller screen says Light Error.
Module Status
Possible Cause
Corrective Action
1. The LED is solid green.
1. There is a short in the work light wires
or the work light assembly.
1. Replace the wires or work light
assembly.