Pre-Wet Error
The center of the controller screen says Pre-Wet Error.
Module Status
Possible Cause
Corrective Action
1. The circuit to the pump is open.
1. Check for disconnected pump wires and
connect them.
2. The maximum current has been
exceeded.
2. Replace the pump.
1-3. The LED is solid green.
3. The pump motor wiring has shorted.
3. Check for shorts in the pump wires.
Replace the pump if necessary.
Vibrator Error
The center of the controller screen says Vib. Error.
Module Status
Possible Cause
Corrective Action
1. The circuit between the module and the
vibrator is open.
1. Check for disconnected wires and
connect them.
2. There is a short in the wires to the
vibrator.
2. Replace the vibrator wire harness.
1-3. The LED is solid green.
3. The vibrator is not functioning.
3. Replace the vibrator.
Feeder Error
The left side of the controller screen says Feeder Error.
Module Status
Possible Cause
Corrective Action
1. The feeder motor is not connected to
the module.
1. Connect the feeder motor to the module.
1-2. The LED is solid green.
2. There is a short in the feeder motor or
feeder motor wires.
2. Replace the feeder motor.
27
Содержание VBX 6500
Страница 31: ...Notes ...
Страница 32: ......