Feeder Jam Error
The left side of the controller screen says Feeder Jam.
Module Status
Possible Cause
Corrective Action
1. The LED is solid green.
1. The auger or pintle chain is jammed.
1. Allow the spreader to clear the jam.
Auger spreaders will pulse forward 3 times,
then cycle between forward and reverse 4
times. Pintle spreaders will pulse forward
7 times.
Feeder Jam Stuck Error
The left side of the controller screen says Feeder Jam Stuck.
Module Status
Possible Cause
Corrective Action
1. The LED is solid green.
1. The auger or pintle chain is jammed and
cannot clear itself.
1. Turn the controller off and on again. If
this error occurs a second time, disconnect
the power to the spreader and free the jam
manually.
Feeder Motor Cool Error
The left side of the controller screen says Feeder Motor Cool and there is a fan icon.
Module Status
Possible Cause
Corrective Action
1. The LED is solid green.
1. The feeder circuit has reached Feeder
Jam Stuck 7 times without freeing itself.
1. Let the spreader feed motor cool for 3
minutes, then turn the controller off and
on again, or disconnect the power to the
spreader and free the jam manually.
The feeder motor is running but the auger or pintle chain is not moving.
There is no error icon for this item.
Module Status
Possible Cause
Corrective Action
1. The drive system is not connected to
the gearbox.
1. Replace the coupling and/or the
gearbox.
1-2. The LED is solid green.
2. The key has fallen out of the coupling.
2. Replace the coupling and key.