84
en | Configuration via IP, Advanced Mode
Dinion IP Infrared Imager
F.01U.263.416 | 3.1 | 2012.09
User Manual
Bosch Security Systems, Inc.
2.
If necessary, click
Clear All
first to clear the current
selection (fields marked yellow).
3.
Left-click the fields to be activated. Activated fields are
marked yellow.
4.
If necessary, click
Select All
to select the entire video
frame for monitoring.
5.
Right-click any fields that you want to deactivate.
6.
Click
OK
to save the configuration.
7.
Click the close button
X
in the window title bar to close
the window without saving the changes.
9.5.3
Alarm E-Mail
As an alternative to automatic connecting, alarm states can also
be documented by e-mail. In this way it is possible to notify a
recipient who does not have a video receiver. In this case, the
camera automatically sends an e-mail to a previously defined e-
mail address.
Send alarm e-mail
Select
On
if you want the unit to automatically send an alarm e-
mail in the event of an alarm.
Mail server IP address
Enter the IP address of a mail server that operates on the SMTP
standard (Simple Mail Transfer Protocol). Outgoing e-mails are
sent to the mail server via the address you entered. Otherwise
leave the box blank (
0.0.0.0
).
SMTP user name
Enter a registered user name for the chosen mailserver here.
SMTP password
Enter the required password for the registered user name here.
Format
You can select the data format of the alarm message.
–
Standard (with JPEG)
- E-mail with attached JPEG image
file.
–
SMS
- E-mail in SMS format to an e-mail-to-SMS gateway
(for example to send an alarm by cellphone) without an
image attachment.