Dinion IP Infrared Imager
Configuration via IP, Advanced Mode | en
75
Bosch Security Systems, Inc.
User Manual
F.01U.263.416 | 3.1 | 2012.09
Specify the numbers of the IP addresses to be contacted in the
event of an alarm. The unit contacts the remote stations one
after the other in the numbered sequence until a connection is
made.
Destination IP address
For each number, enter the corresponding IP address for the
desired remote station.
Destination password
If the remote station is password protected, enter the
password here.
In this page, you can save a maximum of ten destination IP
addresses and hence up to ten passwords for connecting to
remote stations. If connections to more than ten remote
stations are to be possible, for example when initiating
connections via higher-ranking systems such as VIDOS or Bosch
Video Management System, you can store a general password
here. The camera can use this general password to connect to
all remote stations protected with the same password. In this
case, proceed as follows:
1.
Select
10
from the
Number of destination IP address
list
field.
2.
Enter the address
0.0.0.0
in the
Destination IP address
field.
3.
Enter your chosen password in the
Destination password
field.
4.
Define this password as the
user
password for all remote
stations to which a connection is to be possible.
Video transmission
NOTICE!
If you enter the destination IP address 0.0.0.0 for destination
10, this address will no longer be used for the tenth attempt at
automatic connection in the event of an alarm. The parameter is
then used only to save the general password.