PSTN (Contact ID) over GSM Mode
Table 4.3
PSTN (Contact ID) over GSM Mode SMS Configuration
Multiple SMS Messages (for Messages Longer than 160 Characters)
Table 4.4
Double SMS Example, Part 1
Table 4.5
Double SMS Example, Part 2
4.1.3
Send the Configuration SMS
1.
Send the configuration SMS to the SIM card phone number. The transmission might take
several minutes. Because the CONFIG jumper is on, the ITS-DX4020-G waits for an SMS
until a message is received.
2.
Observe the LEDs on the ITS-DX4020-G.
When all of the LEDs start a scrolling pattern, the ITS-DX4020-G is successfully
configured. Refer to
for more information.
ID
Description
Sample SMS
%1
SMS sequence number 1
1=
Current password (4 to 15 characters);
default = 4020G
14=
Control panel bus address 0 to set it to PTSN (Contact ID)
over GSM mode
17=
Communication path:
–
1 = Both
(default)
–
2 = IP over GPRS
–
3 = PSTN (Contact ID) over GSM
1
!
End of configuration
1
Select
3 (PSTN (Contact ID) over GSM)
for PSTN over GSM Mode
ID
Description
Sample SMS
%1<LF>
SMS sequence number 1
1=4020G<LF>
Current password
2=secret123<LF>
New password (case sensitive)
3=123456,4343<LF>
PUK and new PIN to set in SIM
10=basic.m2m<LF>
(Access Point Name) APN
GPRS username
12=password<LF>
GPRS password
15=1<LF>
Enable AES encryption
16=01020304050607080910
111213141516<LF>
Sample AES key
ID
Description
Sample SMS
%2<LF>
SMS sequence number
14=134<LF>
Option bus address
!
End of configuration
%1
1=4020G
14=0
17=3
!
%1
1=4020G
2=secret123
3=123456,4343
10=basic.m2m
[email protected]
12=password
15=1
16=01020304050607080910111213141516
%2
14=134
!